• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TRIPATH IMAGING, INC VIAL SUREPATH COLLECTION KIT 500; PROCESSOR, CERVICAL CYTOLOGY SLIDE, AUTOMATED

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TRIPATH IMAGING, INC VIAL SUREPATH COLLECTION KIT 500; PROCESSOR, CERVICAL CYTOLOGY SLIDE, AUTOMATED Back to Search Results
Catalog Number 491452
Device Problems Crack (1135); Leak/Splash (1354)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/27/2023
Event Type  malfunction  
Manufacturer Narrative
E.6 initial reporter e-mail: (b)(6) e.7 initial reporter addr 1: (b)(6) h.3.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
Report 9 of 9.It was reported that while using vial surepath collection kit 500 that there was a vial cracked that continued a patient sample.The following information was provided by the initial reporter: was the incident noted before, during or after the use of the reagent? after if the vials were used, were there any loss of patient samples? yes , due to the reported broken cap defect cause a leak and the leaking affect the identification label of 9 patient samples, new samples were taken, and results were delayed.If so, was it necessary to take new samples from the patients? yes was there a delay in the diagnosis of the patients? yes the cap broke from the upper part, on other occasions they only spill, i am also reviewing this issue with logistics, the vials are from lot: 2304652.
 
Manufacturer Narrative
Report 9 of 9.It was reported that while using vial surepath collection kit 500 that there was a vial cracked that contained a patient sample.H6.Investigation summary: the customer complaint is for three (3) instances in the previous three (3) months of cracked caps on vials causing sample leakage (post sample collection) from item 491452, lot number 2304652.Material 491452 is produced at the bd mebane, nc facility on a validated automated manufacturing line referred to as the shibuya vial filling line.The capper section of the shibuya vial filling line contains eight (8) capper heads, which caps the vials to a validated application torque controlled by servo motor.The capper is validated to inspect for application torque and unseated or missing caps.Vials that fail to meet inspection requirements (i.E., outside of the validated application torque) are rejected automatically after the capper section.To ensure that the capper remains in validated state, a quarterly preventive maintenance (pm) is established that is used to confirm accuracy of application torque for each of the eight (8) heads.The pm is performed by using a calibrated servo torque verifier that is compared against the shibuya cap application torque value.Production of material 491452 lot 2304652 started on 02nov2022.A review of the two (2) pm events that bracketed the production date identified that the results of the verification were acceptable.Further review identified that there has never been a failure of the servo torque verification pm events.A review of the maintenance history on the capper identified no equipment repairs that could be correlated to the complaint event.A total of 432 kits (216,000 vials) were produced and were inspection using ansi general level ii, single sampling, normal, at an aql of 0.65%.A total of 800 vials were qc inspected prior to product disposition with a total of 0 defects observed.An additional 800 vials were leak tested in a vacuum chamber during in-process testing and identified 1 leaking or cracked cap defects.The dhr did not contain clarification if a cracked cap contributed to the leaking vial.The review of the manufacturing dhr for the lot number identified that it was complete and accurate with no indication of abnormal activities during manufacturing.The review of the bill of materials (bom) for 491452 lot 2304652 identified that raw cap lot number material 700030951 lot number 2222109 was used during the production.Raw cap item number 700030951 is inspected using ansi general level ii, single sampling, normal, at an aql of 0.65%.A review of the incoming inspection results for 700030951 lot number 2222109 identified 800 caps were inspected from each lot and passed the acceptance criteria with zero defects identified.A visual retain analysis was performed on one clamshell (25 vials) from item 491452, lot 2304652.No cracked caps were identified during the retain analysis.A sample was not returned to the mebane, nc facility for evaluation.However, multiple pictures were provided that confirm vials with cracked caps.The cracks are horizontal cracks at the near the top of the cap (near location of thread run out).Therefore, the complaint is confirmed.A 12-month complaint review for the defect mode of cracked cap was performed and identified previous complaints for the item number but no previous cracked cap complaints for the lot number.Bd will continue to monitor and evaluate trends.
 
Event Description
Report 9 of 9.It was reported that while using vial surepath collection kit 500 that there was a vial cracked that contained a patient sample.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VIAL SUREPATH COLLECTION KIT 500
Type of Device
PROCESSOR, CERVICAL CYTOLOGY SLIDE, AUTOMATED
Manufacturer (Section D)
TRIPATH IMAGING, INC
1022 corporate park drive
mebane NC 27302
Manufacturer (Section G)
TRIPATH IMAGING, INC
1022 corporate park drive
mebane NC 27302
Manufacturer Contact
jennifer suh
5859 farinon drive
san antonio, TX 78249
8448235433
MDR Report Key17572886
MDR Text Key321819168
Report Number3008007472-2023-00017
Device Sequence Number1
Product Code MKQ
UDI-Device Identifier10382904914520
UDI-Public10382904914520
Combination Product (y/n)N
Reporter Country CodeMX
PMA/PMN Number
P970018
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 12/11/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number491452
Device Lot Number2304652
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 07/27/2023
Initial Date FDA Received08/18/2023
Supplement Dates Manufacturer Received12/11/2023
Supplement Dates FDA Received01/08/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured10/31/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-