SCHILLER AG TEMPUS LS; DEFIBRILLATOR Back to Search Results
Model Number 00-3020
Device Problem Pacing Problem (1439)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/26/2023
Event Type  malfunction  
Manufacturer Narrative
Philips is in the process of obtaining additional information concerning this event and the complaint is still under investigation.A final report will be submitted once the investigation is complete.
 
Event Description
It was reported the device would not pace during a training class.There was no patient involvement.
 
Manufacturer Narrative
This report is based on information provided by a philips field service engineer and schiller (manufacturer) and has been investigated by the philips complaint handling team.A replacement device was sent to the customer.The log and rescue files and the device were received at schiller where a technical investigation was completed.Error 26 was observed on the log file due to loss of communication most likely due to a hardware failure.Schiller has identified that the defibrillator/pacemaker module (dpm) may encounter an issue where communication from the device mainboard and the dpm board fails.The device was removed from service at schiller.Based on the information available and the testing conducted, the cause of the reported problem was a communication error from the main board to the dpm module, error 26 was observed on the logfile.The reported problem was confirmed.A replacement device was provided.The investigation concludes that no further action is required at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TEMPUS LS
Type of Device
DEFIBRILLATOR
Manufacturer (Section D)
SCHILLER AG
altgasse 68
baar 6341
SZ  6341
Manufacturer (Section G)
SCHILLER AG
altgasse 68
baar 6341
SZ   6341
Manufacturer Contact
tanya deschmidt
ascent 1, aerospace centre
aerospace boulevard
farnborough GU14 -6XW
UK   GU14 6XW
MDR Report Key17620561
MDR Text Key321949040
Report Number3003832357-2023-00563
Device Sequence Number1
Product Code LDD
UDI-Device Identifier07613365002737
UDI-Public07613365002737
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K200849
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/24/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number00-3020
Device Catalogue Number989706001681
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received07/26/2023
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-