DATASCOPE CORP. - FAIRFIELD YAMATO PLUS-R 7.5FR. 35CC IAB; SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL Back to Search Results
Catalog Number 0684-00-0549-02
Device Problems Restricted Flow rate (1248); Inappropriate Waveform (2536)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/23/2023
Event Type  malfunction  
Event Description
It was reported that after about 5 minutes of intra-aortic balloon (iab) therapy, there was no waveform being generated from the inner lumen.A syringe was connected directly to the inner lumen in an attempt to apsirate blood from the lumen, but was unable to successfully aspirate.The iab was replaced and therapy was provided.There was no reported injury to the patient.
 
Manufacturer Narrative
Event site postal code: (b)(6).The device has not been returned to the manufacturer so we are unable to complete an evaluation.Reference complaint (b)(4).Device not returned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
YAMATO PLUS-R 7.5FR. 35CC IAB
Type of Device
SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL
Manufacturer (Section D)
DATASCOPE CORP. - FAIRFIELD
15 law drive
fairfield NJ
Manufacturer (Section G)
DATASCOPE CORP. - FAIRFIELD
15 law drive
fairfield NJ
Manufacturer Contact
brian schaeffer
15 law drive
fairfield, NJ 
MDR Report Key17653491
MDR Text Key322320470
Report Number2248146-2023-00537
Device Sequence Number1
Product Code DSP
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,User Facility,Company Representative
Reporter Occupation Other
Type of Report Initial
Report Date 08/30/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/30/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number0684-00-0549-02
Device Lot Number3000292872
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Date Manufacturer Received08/24/2023
Was Device Evaluated by Manufacturer? No
Date Device Manufactured01/25/2023
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Treatment
EDWARDS PRESSURE TRANSDUCER
-
-