• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SIRONA DENTAL, INC. SCHICK33 S2 SENSOR STARTER KIT/3.0 INTERFACE 6FT; UNIT, X-RAY, INTRAORAL, PRODUCT CODE: EAP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SIRONA DENTAL, INC. SCHICK33 S2 SENSOR STARTER KIT/3.0 INTERFACE 6FT; UNIT, X-RAY, INTRAORAL, PRODUCT CODE: EAP Back to Search Results
Catalog Number 100008633
Device Problem Image Display Error/Artifact (1304)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
While no serious injury resulted in this event, if this malfunction recurred, it could cause or contribute to a serious injury or require medical or surgical intervention to preclude such.This event, therefore, is reportable per 21cfr part 803.Usb 3 firmware v1.4 contains an issue in the portion of code used to optimize sensor performance.If the optimization occurs during an exposure or sensor readout, there is a chance that the resulting image will be corrupted.Image data following the point of corruption will consist of data that was previously held in the memory of the usb device.As a result, the presented image may contain a portion of data from a previous exposure.In general, this would be obvious to the user since the presented image would either contain obvious artifacts or different anatomy than expected.
 
Event Description
While using a schick 33 sensor intraoral x-ray unit, an incorrect image was displayed during use.This was immediately noticeable to the clinician and no injury resulted.
 
Manufacturer Narrative
Device that was reported initially for this event is being corrected from schick 33 with ae usb to schick33 s2 sensor starter kit/3.0 interface 6ft.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SCHICK33 S2 SENSOR STARTER KIT/3.0 INTERFACE 6FT
Type of Device
UNIT, X-RAY, INTRAORAL, PRODUCT CODE: EAP
Manufacturer (Section D)
SIRONA DENTAL, INC.
30-30 47th ave.
suite 500
long island city NY 11101
Manufacturer (Section G)
SIRONA DENTAL, INC.
30-30 47th ave.
suite 500
long island city NY 11101
Manufacturer Contact
hannah seevaratnam
221 w. philadelphia st.
york, PA 17401
7178494593
MDR Report Key17736321
MDR Text Key323276803
Report Number2436911-2023-00013
Device Sequence Number1
Product Code EAP
UDI-Device IdentifierD764100008633
UDI-PublicD764100008633
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K093453
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Dentist
Type of Report Initial,Followup
Report Date 09/13/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue Number100008633
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/28/2023
Initial Date FDA Received09/13/2023
Supplement Dates Manufacturer Received08/28/2023
Supplement Dates FDA Received09/13/2023
Was Device Evaluated by Manufacturer? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-