• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION INTERLOCK-35; DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION INTERLOCK-35; DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION Back to Search Results
Model Number 83787
Device Problems Break (1069); Difficult to Remove (1528); Stretched (1601); Failure to Advance (2524)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/07/2023
Event Type  malfunction  
Event Description
It was reported that the coil was fractured.The target lesion was located in the splenic artery with multiple aortic aneurysms.A 10mm x 40cm.035 interlock cube coil was selected for use.During the procedure, the device was delivered normally into the non-boston scientific contrast catheter.However, when the physician continued to push the coil, the coil got stuck and broke at the opening of the contrast catheter.The coil could not be pulled back.The physician withdraws the coil together with the delivery system.The contrast between the coil and the catheter was found stretched at the place of the fracture.The physician tried to continue to use the device and cut off the stretched and broken part and tried to place the released coil, which was exposed outside of the delivery system, into the contrast catheter, but ultimately failed.The procedure was completed with a different device.No complications were reported, and the patient was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTERLOCK-35
Type of Device
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORK LIMITED
model farm road
cork T12 Y K88
EI   T12 YK88
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key17793001
MDR Text Key323975281
Report Number2124215-2023-50927
Device Sequence Number1
Product Code KRD
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K133208
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,Company Representative,Distributor
Reporter Occupation Physician
Type of Report Initial
Report Date 09/21/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/21/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number83787
Device Catalogue Number83787
Device Lot Number0031856845
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received09/08/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/20/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
MICROCATHETER: CORDIS5F
Patient Age65 YR
Patient SexMale
Patient Weight65 KG
-
-