|
Catalog Number EMAX2PLUS |
Device Problems
Material Frayed (1262); Unintended System Motion (1430); Excessive Heating (4030)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 09/18/2023 |
Event Type
malfunction
|
Event Description
|
It was reported from india that during service and evaluation, it was determined that the motor device had cable damage, cord damage, could not secure/lock the cutter device, had component damage, had unintended activation/motion, device runs in an unexpected direction/mode, had heat, and the speed could not be controlled/changed.It was further determined that the device failed pretest for visual assessment, cable assessment, cutter lock assessment, motor thermistor assessment, safety assessment, direction control assessment, handpiece temperature assessment, and hand control assessment.It was noted in the service order that the outer cable covering of the motor device was damaged.This event did not occur during surgery.There was no patient involvement.There were no reports of injuries, medical intervention, or prolonged hospitalization.All available information has been disclosed.If additional information should become available, a supplemental medwatch will be submitted accordingly.
|
|
Manufacturer Narrative
|
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for this medwatch, a supplemental medwatch report will be filed as appropriate.H10 additional narrative: the actual device was returned for evaluation.During repair, an evaluation was performed and it was determined that the device had cable damage, heat, and unintended activation/motion.Therefore, the reported condition was confirmed.The assignable root cause of this condition was determined to be traced to component failure due to wear.Udi - (b)(4).
|
|
Search Alerts/Recalls
|
|
|