Catalog Number NSLG2C35
Device Problems Device Alarm System (1012); Difficult to Open or Close (2921)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/30/2023
Event Type  malfunction  
Event Description
It was reported that during an unknown procedure it does not open the clamp correctly, as if they will stick.He tries to work with the tweezers and after 5 minutes, it stays completely stuck, and he takes out the tweezers and tries to open them and succeeds.Subsequently, they report that they no longer open again and a legend "replace product" appears on the console, to which another one is provided new caliper.There were no patient consequences.
 
Manufacturer Narrative
(b)(4).Date sent: 10/4/2023.D4 batch #: unknown.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformance were identified.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENSEAL G2 CURVED JAW 35CM
Type of Device
ELECTROSURGICAL CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
*  00969
Manufacturer (Section G)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
*   00969
Manufacturer Contact
kate karberg
475 calle c
guaynabo 
*  
3035526892
MDR Report Key17868567
MDR Text Key324890674
Report Number3005075853-2023-07191
Device Sequence Number1
Product Code GEI
UDI-Device Identifier10705036014140
UDI-Public10705036014140
Combination Product (y/n)N
Reporter Country CodeMX
PMA/PMN Number
K112033
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Company Representative
Reporter Occupation Other
Type of Report Initial
Report Date 10/04/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberNSLG2C35
Device Lot NumberX9685U
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 09/13/2023
Initial Date FDA Received10/04/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/11/2022
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Treatment
GENERATOR
-
-