• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TORNIER INC PERFORM HUMERAL HEAD IMPACTOR TIP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TORNIER INC PERFORM HUMERAL HEAD IMPACTOR TIP Back to Search Results
Catalog Number MWM054
Device Problems Break (1069); Fracture (1260); Material Fragmentation (1261)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/21/2023
Event Type  malfunction  
Manufacturer Narrative
Once the investigation has been completed any additional information will be reported in a supplemental report.
 
Event Description
As reported: "impactor tip broke into pieces.".
 
Event Description
As reported: "impactor tip broke into pieces.".
 
Manufacturer Narrative
The reported event could be confirmed, since the product was returned for evaluation and matches the alleged failure mode.The device inspection revealed the following: the received device shows significant signs of extensive usage as evident by wear marks & blue spots.Breakage is evident as the device is almost broken into two pieces at the proximal end where the humeral head of impactor connects the handle.A review of the device history for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.No indications of material & manufacturing related problems were found during the investigation.A review of the labeling did not indicate any abnormalities.Based on investigation, the root cause was attributed to wear & design related issue.The failure was caused by its intended use.As a device that is manufactured of radel plastic and incurs numerous impaction events, cleaning and sterilization cycles, breakage as noted in this complaint can be expected.However, this event has been escalated to a nc and capa were opened to update the design of this part.If any further information is provided, the complaint report will be updated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERFORM HUMERAL HEAD IMPACTOR TIP
Type of Device
IMPACTOR
Manufacturer (Section D)
TORNIER INC
10801 nesbitt avenue s
bloomington MN 55437
Manufacturer (Section G)
TORNIER INC
10801 nesbitt avenue s
bloomington MN 55437
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key17988968
MDR Text Key326315562
Report Number0001649390-2023-00279
Device Sequence Number1
Product Code HWA
UDI-Device Identifier00846832082964
UDI-Public00846832082964
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Distributor
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 12/04/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue NumberMWM054
Device Lot NumberCV0121341
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 09/25/2023
Initial Date FDA Received10/23/2023
Supplement Dates Manufacturer Received11/07/2023
Supplement Dates FDA Received12/04/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/09/2022
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-