Model Number 865240
Device Problem Device Alarm System (1012)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/30/2023
Event Type  malfunction  
Manufacturer Narrative
A follow up report will be submitted once the investigation is complete.
 
Event Description
The customer reported that the intellivue mx800 patient monitor issued a yellow alarm instead of the expected red alarm.It is unknown if the device was in use at time of event, and there was no adverse event reported.
 
Manufacturer Narrative
Philips received a complaint on the intellivue mx800 patient monitor indicating that the yellow alarm went off instead of red.A remote service engineer (rse) spoke with the customer and explained that the heart rate (hr) needed to be above the set limit for a ventricular tachycardia (v-tach).The patient had premature ventricular contractions (pvcs), which is why the customer got the yellow alarm.The rse advised that there had to be a hr violation as well in order to get the red alarm for v-tach.Based on the information available and the testing conducted, the device was functioning as intended, and there was no malfunction of the device.The reported problem was not confirmed.The device was confirmed to be operating per specifications and no failure was identified.The investigation concludes that no further action is required.The device remains at the customer site.
 
Event Description
The customer reported that the intellivue mx800 patient monitor issued a yellow alarm instead of the expected red alarm.The device was in use monitoring a patient at the time of the reported issue.No adverse patient or user event was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTELLIVUE MX800 PATIENT MONITOR
Type of Device
INTELLIVUE MX800 PATIENT MONITOR
Manufacturer (Section D)
PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH
hewlett-packard-str. 2,
b1-3/d6
boblingen 71034
GM  71034
Manufacturer (Section G)
PHILIPS MEDIZIN SYSTEME BÖBLINGEN GMBH
hewlett-packard-str. 2,
b1-3/d6
boblingen 71034
GM   71034
Manufacturer Contact
hauke schik
hewlett-packard-str. 2,
b1-3/d6
boblingen 71034
GM   71034
7031463203
MDR Report Key18013207
MDR Text Key326632670
Report Number9610816-2023-00549
Device Sequence Number1
Product Code DSI
UDI-Device Identifier00884838020733
UDI-Public00884838020733
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K150310
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number865240
Device Catalogue Number865240
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/30/2023
Initial Date FDA Received10/26/2023
Supplement Dates Manufacturer Received11/27/2023
Supplement Dates FDA Received11/30/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/06/2019
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-