COVIDIEN EVERFLEX SELF-EXPANDING PERIPHERAL STENT WITH ENTRUST DELIVERY SYSTEM LONG; STENT, SUPERFICIAL FEMORAL ARTERY
|
Back to Search Results |
|
Catalog Number EVX35-05-150-120 |
Device Problems
Fracture (1260); Activation, Positioning or Separation Problem (2906); Noise, Audible (3273)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 10/07/2023 |
Event Type
malfunction
|
Manufacturer Narrative
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
A physician was attempting to implant an everflex entrust for treatment of a lesion in the mid superficial femoral artery.There was mild tortuosity and no calcification.The device was prepped as per the ifu with no issues identified.The lock-pin was checked for securement prior to the procedure.The lesion was pre-dilated with a 5.0x150mm pre-dilation device.The device did not pass through a previously deployed stent and no resistance was med during advancement.The lock-pin was removed when the stent was in position.It was reported during deployment an abnormal sound was heard from the delivery system and the physician tried to remove it, by doing this the hydrophilic guide broke and detached, the physician disassembled the release handle, he could not release the stent and finally he pulled everything out to remove it from the patient since the stent was not released from the system.No patient injury was reported.
|
|
Manufacturer Narrative
|
Image analysis three images and a video were provided for evaluation.The images provided show the device out on a table.Biologics can be observed on the device.There appears to be a wire loaded in the device.Part of the device is protruding out of the handle where the locking pin was removed.In one of the images you can see the handle is open and the wheel has been removed from the handle.The wire appears to be attached to the wheel and no break can be observed.There was no detachment observed to the device.The stent can be observed to be slightly deployed.There appears to be bends on the device.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Search Alerts/Recalls
|
|
|