MAUDE Adverse Event Report: BAXTER HEALTHCARE CORPORATION SOLUTION SETS; SET, ADMINISTRATION, INTRAVASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BAXTER HEALTHCARE CORPORATION SOLUTION SETS; SET, ADMINISTRATION, INTRAVASCULAR Back to Search Results
Catalog Number EMC9618
Device Problems Fluid/Blood Leak (1250); Material Puncture/Hole (1504)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that there was a hole at the tube under the drip chamber of five (5) solution administration sets that resulted in a leak.The issue was identified during filling.There was no patient involvement.No additional information is available.
 
Manufacturer Narrative
Additional information was added to d4 (expiration date), d9, h3, h4, h6 and h10.H10: two (2) actual samples were received for evaluation; the other three (3) samples were not received and therefore, could not be evaluated.A visual inspection was performed which revealed the tube was incorrectly assembled to the drip chamber (the tube was not inserted over the chamber pipe).The reported condition was verified.The cause of the condition was an incorrect insertion of the tube onto the chamber pipe during the automated assembly process.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SOLUTION SETS
Type of Device
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
Manufacturer (Section G)
BAXTER HEALTHCARE - MALTA
a47 industrial estate
marsa
MT  
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
2242702068
MDR Report Key18021974
MDR Text Key326740157
Report Number1416980-2023-05512
Device Sequence Number1
Product Code FPA
UDI-Device Identifier05413760141718
UDI-Public(01)05413760141718
Combination Product (y/n)N
Reporter Country CodeTH
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Company Representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date 12/04/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/27/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberEMC9618
Device Lot Number23D08V160
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Manufacturer Received11/20/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/01/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1