Device Problems
Break (1069); Adverse Event Without Identified Device or Use Problem (2993); Migration (4003)
|
Patient Problem
Insufficient Information (4580)
|
Event Type
malfunction
|
Event Description
|
Device report from synthes reports an event in india as follows: this report is being filed after the review of the following journal article: a.K singh, mbbs, ms., et al., (2017), treatment of unstable trochanteric femur fractures: proximal femur nail versus proximal femur locking compression plate, the american journal of orthopedics 46(2), e116-e123 (india).This study aims to compare functional outcomes and complications of unstable trochanteric fractures treated with proximal femur nail and those treated with proximal femoral locking compression plate.From (b)(6) 2009 to (b)(6) 2011, a total of 48 patients were included in the study.One patient died of causes unrelated to an implant during the study, and 2 were lost to follow up (telephone numbers changed).The remaining 45 patients: (23 pfn male=9, female 14) and (22 pflcp male=7, female=15).Pfn patients received 2 femoral neck screws (depuy synthes) and pflcp patients received pflcp (depuy synthes) in a fashion similar to that described in ao internal fixation manuals.All cases were followed up for 2 years.The following complications were reported as follows: pfn (proximal femur nail).Superficial infection (n=2).Local-site pain (n=2).Nonunion (n=1).Implant-related breakage (n=1).Unrelated to fracture (eg, bed sore, chest infection, urinary tract infection, deep vein thrombosis) (n=1).Revision surgery (n=2) (1 bipolar hemiarthroplasty and 1 removal of protruding screw).Shortening (>2cm) (n=2).Pflcp ( proximal femoral locking compression plate).Superficial infection (n=3).Local-site pain (n=1).Unrelated to fracture (eg, bed sore, chest infection, urinary tract infection, deep vein thrombosis) (n=2).Shortening (>2cm) (n=1).A copy of the literature article is being submitted with this medwatch.This report involves one unk - nails: femoral proximal.This is report 3 of 5 for (b)(4).
|
|
Manufacturer Narrative
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10 additional narrative: d1, d2a, d2b, d3, d4, g4 ¿ 510k: this report is for an unknown nails: femoral proximal/unknown lot.Part and lot numbers are unknown; udi number is unknown.D9: complainant part is not expected to be returned for manufacturer review/investigation.E1: initial reporter phone number was reported as (b)(6).H3, h4, h6: without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Search Alerts/Recalls
|
|
|