Catalog Number 80223 |
Device Problem
Detachment of Device or Device Component (2907)
|
Patient Problems
Extravasation (1842); Perforation (2001); Perforation of Vessels (2135)
|
Event Date 10/26/2023 |
Event Type
Injury
|
Event Description
|
It was reported that during a recanalization procedure in the right iliac artery, the patient allegedly experienced perforation of the external iliac artery and had extravasation of the right external iliac artery.It was further reported that the wire was allegedly withdrawn from the patient by the catheter and caused the gold tip of the wire to uncoil.Reportedly, the covered stenting of the right external iliac artery was performed to treat extravasation.The procedure was completed using another device.The patient is reported to be stable now.
|
|
Manufacturer Narrative
|
H10: the medical device manufacturer (d3) and manufacturing location (g1) for the straub product was selected as unknown due to system limitations.The correct medical device manufacturer and manufacturing location are straub medical us.H10: the catalog number identified in section d4 has not been cleared in the us but is similar to the rotarex products that are cleared in the us.The pro code and 510 k number for the rotarex products are identified in d2 and g4.H10: as the lot number for the device was not provided, a review of the device history records could not be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device not returned.
|
|
Event Description
|
It was reported that during a recanalization procedure in the right iliac artery, the patient allegedly experienced perforation of the external iliac artery and had extravasation of the right external iliac artery.It was further reported that the wire was allegedly withdrawn from the patient by the catheter and caused the gold tip of the wire to uncoil.Reportedly, the covered stenting of the right external iliac artery was performed to treat extravasation.The procedure was completed using another device.The patient is reported to be stable now.
|
|
Manufacturer Narrative
|
H10: the medical device manufacturer (d3) and manufacturing location (g1) for the straub product was selected as unknown due to system limitations.The correct medical device manufacturer and manufacturing location are straub medical us.H10: the catalog number identified in section d4 has not been cleared in the us but is similar to the rotarex products that are cleared in the us.The pro code and 510 k number for the rotarex products are identified in d2 and g4.H10: manufacturing review: as the lot number for the device was not provided, a review of the device history records could not be performed.Investigation summary: the sample was not returned for evaluation and a physical investigation was not possible.Also, no images or videos were provided for review.The user reported damage of the guidewire, due to sample reported malfunction cannot be confirmed.Therefore, the investigation is inconclusive for the reported issue.A clear root cause could not be identified but a damaged guidewire represents a known inherent risk.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.H11: h6 (patient).H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
|