MICROVENTION, INC SOFIA FLOW PLUS 6F-127CM STR; PERCUTANEOUS CATHETER/ DIAGNOSTIC INTRAVASCULAR CATHETER Back to Search Results
Model Number UNKNOWN
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Intracranial Hemorrhage (1891)
Event Date 11/08/2022
Event Type  Injury  
Manufacturer Narrative
The device was not returned to the manufacturer for evaluation.Procedural or medical imaging was not provided.The alleged subarachnoid blood-sah and issues as described could not be confirmed.The model and lot numbers were not provided; therefore, a search for production-related ncrs could not be performed at this time.
 
Event Description
As reported through the clinical study sofast axiom id: (b)(4) sub.Id: (b)(4): date of original surgery was on (b)(6) 2022.Patient had diagnostic ct scan on unknown date.On (b)(6) 2022, it was found that the subject has small contrast staining vs hemorrhage later found to be subarachnoid blood -sah that resolved without sequelae.Based on the information provided the reported event#: 001 - subarachnoid blood-sah, is indicated as possibly related to the study device, sofia and thrombectomy procedure.Device was a "sofia 6f aspiration catheter - 0.070" id / 125 cm, however the lot number is not known at this time.Event term: subarachnoid hemorrhage.Event start date: 08/nov/2022.Event type: neurological, asymptomatic.Event outcome: resolved.Relationship to sofia device: possibly.Relationship to mechanical thrombectomy procedure: possibly.Relationship to study disease: definitely.
 
Event Description
No additional information was received, please see h6 and h10.
 
Manufacturer Narrative
Items returned: - n/a visual analysis: a visual inspection of the device captured in this file could not be performed as a physical device was not returned for evaluation, nor were any images of the device provided in place of a device return.Procedure and medical imaging was not provided for this investigation.Investigation findings: without the return and physical evaluation of the device, the investigation cannot definitively determine if a condition existed that would have caused or contributed to the reported event.Without imaging, the investigation cannot verify the event occurred as described, nor could the investigation definitively determine the cause of the reported event.Based on a review of the device¿s risk documentation, the reported event did not indicate there were any potential or new manufacturing, design, quality, or other systemic issues, or non-conformances.The complaint code is monitored through the trending process; corrective action is determined, as needed, through this process.Investigations of historic complaint files with similar complaint category coding are recorded in the complaint handling system; without the ability to perform and analysis of the device, this investigation cannot identify with certainty any potential root causes.Batch review: a search for non-conformances associated with this part/lot number combination could not be performed as this information was not available at the time this investigation was performed.Complaint system review: a search of the complaint handling system could not be performed to determine if other similar complaints exist for this batch number, because the batch number was not provided for the product on this complaint file.Ifu review (additional information can be found in the ifu, the following is taken from the 27 language version): potential complications potential complications include, but are not limited to: vessel or aneurysm perforation, vasospasm, hematoma at the site of entry, embolism, ischemia, intracerebral/intracranial hemorrhage, pseudo aneurysm, seizure, stroke, infection, vessel dissection, thrombus formation, and death.Precautions exercise care in handling the sofia¿ catheter to reduce the chance of accidental damage.Use caution when manipulating the sofia¿ catheter in tortuous vasculature to avoid damage.Avoid advancing or withdrawal against resistance until the cause of resistance is determined.Presence of calcifications, irregularities, or other devices may damage the sofia¿ catheter and potentially affect its insertion or removal.Maintain perfusion of heparinized saline for inner lumen of the sofia¿ catheter to prevent thrombus formation.If removed from the patient, the hydrophilic coating on the sofia¿ catheter should be hydrated with heparinized saline.Do not allow the coating to dry.Delivery of the sofia¿ catheter 6.Go to step 7 or 8, depending on the situation described below and choose appropriate devices for navigation of the sofia¿ catheter.7.Navigation through the vasculature, except for the intracranial vasculature c.Using the introducer sheath provided in the package, carefully insert the sofia¿ catheter and the guidewire through a hemostatic valve of the femoral sheath.E.Under fluoroscopic guidance, advance or withdraw the sofia¿ catheter over the guidewire until desired position is attained or before the intracranial position is achieved.Select vessels by slowly torquing the sofia¿ catheter if necessary.Warning: do not advance or withdraw the device when excessive resistance is met until the cause of resistance is determined.Warning: torquing the sofia¿ catheter excessively while kinked may damage the device resulting in separation of the device.Withdraw the entire device (the device, microcatheter, and guidewire) if the device is severely kinked.Warning: do not exceed 2070 kpa (300 psi) maximum recommended infusion pressure.Excess pressure may damage the device or injure the patient.Carefully monitor placement of the distal tip when using a power injector to infuse.F.Go to step 8 for navigation through the intracranial vasculatures.Otherwise proceed to step 9.8.Navigation through the intracranial vasculature c.Under fluoroscopic guidance, advance or withdraw the sofia¿ catheter over the microcatheter and the guidewire until desired position is attained.Select vessels by slowly torquing the sofia¿ catheter if necessary.Warning: do not advance or withdraw the device when excessive resistance is met until the cause of resistance is determined.Warning: torquing the sofia¿ catheter excessively while kinked may damage the device resulting in separation of the device.Withdraw the entire device (the device, microcatheter, and guidewire) if the device is severely kinked.Warning: do not exceed 2070 kpa (300 psi) maximum recommended infusion pressure.Excess pressure may damage the device or injure the patient.Carefully monitor placement of the distal tip when using a power injector to infuse.Aspiration through the sofia¿ catheter with syringe 7.Make sure that the syringe aspirates blood, emboli, or thrombi through the system.Close the stopcock if the syringe does not aspirate any blood, emboli, or thrombi, or slow aspiration is observed.Carefully investigate the cause of the restriction and reposition the distal tip if necessary.If blood, emboli, or thrombi is stuck in the sofia¿ catheter remove the entire device (the device, microcatheter, and guidewire) and clear the inner lumen.If restriction still remains and the distal tip of the sofia¿ catheter has been repositioned correctly, close the stopcock, re-attach the syringe, and resume aspiration.Maintain aspiration to make sure the emboli or thrombi remains fully engaged with the distal tip of the sofia¿ catheter.With the emboli or thrombi fully engaged pull back the sofia¿ catheter out of the patient body.Warning: excessive aspiration with the distal tip of the sofia¿ catheter covered by the vessel wall may cause vessel injury.8.After aspiration is completed, remove the sofia¿ catheter from the patient body.If re-access to the vasculatures with the same device is desired, flush and clean the inner lumen of the device by infusion.Inspect the device for any damage.Follow steps 6 through 9 in the delivery of the sofia¿ catheter section for navigation.Warning: do not use the device if any damages or irregularities are observed.Aspiration through the sofia¿ catheter with pump 3.Attach aspiration tubing to the aspiration pump and turn on the pump (refer to the directions for use of the aspiration tubing and aspiration pump manual).Confirm that the aspiration gauge reads -20 inhg.Ensure the stopcock on the aspiration tubing is in the closed position.7.To begin aspiration, turn the aspiration tubing stopcock to the open position and check to see if blood, thrombus, or embolus are aspirated through the system.8.If after 10 seconds blood is still observed flowing through the system, stop aspiration.To stop aspiration, turn aspiration tubing stopcock to the closed position.Carefully reposition the distal tip of the sofia¿ catheter to engage the thrombus and resume aspiration.9.If flow is restricted or absent, maintain aspiration to make sure any thrombus or embolus is fully engaged with the distal tip of the sofia¿ catheter.With the thrombus or embolus fully engaged, slowly pull back the sofia¿ catheter and completely withdraw out of the patient.Warning: excessive aspiration with the distal tip of the sofia¿ catheter engaged with vessel wall may cause vessel injury.The physical device was not available for evaluation to determine if a condition existed that would have caused or contributed to event.Supplemental imaging was also unavailable for review; without imaging, the investigation cannot verify the event occurred as described, nor could the investigation definitively determine the cause of the reported event.This information may be updated if additional information is provided at a later date.
 
Manufacturer Narrative
Additional information was received now noting the cec (independent reviewer) adjudication of reported incident determined the incident not to be related to any microvention devices.Based on this new information, the incident would be deemed not reportable.
 
Event Description
Additional information was received noting the cec (independent reviewer) adjudication of the reported incident determined the incident not to be related to any microvention devices.Reported incident is noted to be definately related to study disease.Based on this new information, the incident would be deemed not reportable.Event term: subarachnoid hemorrhage.Event start date: 08/nov/2022.Event type: neurological, asymptomatic.Event outcome: resolved.Date of resolution: 11/nov/2022.Relationship to sofia device: not related.Relationship to eric device: not related.Relationship to bobby bgc device: not related.Relationship to mechanical thrombectomy procedure: possibly.Relationship to study disease: definitely.Relationship to concurrent condition/treatment: possibly.Severity: mild.Is the event an sae?: no.Hemorrhagic transformation?: no.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SOFIA FLOW PLUS 6F-127CM STR
Type of Device
PERCUTANEOUS CATHETER/ DIAGNOSTIC INTRAVASCULAR CATHETER
Manufacturer (Section D)
MICROVENTION, INC
35 enterprise
aliso viejo CA 92656
Manufacturer (Section G)
MICROVENTION, INC
35 enterprise
aliso viejo CA 92656
Manufacturer Contact
terrence callahan
35 enterprise
aliso viejo, CA 92656
7142478000
MDR Report Key18306862
MDR Text Key330225037
Report Number2032493-2023-01106
Device Sequence Number1
Product Code DQY
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K173200
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Study,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 02/23/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/11/2023
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model NumberUNKNOWN
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received02/14/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-