Catalog Number D134801 |
Device Problem
Patient Device Interaction Problem (4001)
|
Patient Problem
Ischemic Heart Disease (2493)
|
Event Date 11/27/2023 |
Event Type
Injury
|
Event Description
|
It was reported that a patient underwent a cardiac ablation procedure for premature ventricular contraction, with a thermocool® smart touch® sf bi-directional navigation catheter, and patient experienced an elevated st segment requiring surgical intervention.The elevated st segment occurred when ablated for summit vpc (premature ventricular contraction) after ablation was conducted in cs (coronary sinus).Emergency pci (percutaneous coronary intervention) with stenting with balloons was performed based on the diagnosis of lcx (left circumflex artery) occlusion.Patient outcome was improved.Lcx flow was recovered and maintained.Patient was followed up in hospital for pericarditis and will be discharged soon.The physician's opinion on the relationship between the event and the product was that the heat from ablating in the cs might have added to the lcx.The ablation was stopped several times due to the impedance monitoring, and the device was working as normal during the operation.There were no abnormalities observed before or while using the product.
|
|
Manufacturer Narrative
|
E 1.Initial reporter phone: (b)(6).If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster, inc., or its employees that the report constitutes an admission that the product, biosense webster, inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Manufacturer's reference number: (b)(4).
|
|
Manufacturer Narrative
|
It was reported that a patient underwent a cardiac ablation procedure for premature ventricular contraction, with a thermocool® smart touch® sf bi-directional navigation catheter, and patient experienced an elevated st segment requiring surgical intervention.The elevated st segment occurred when ablated for summit vpc (premature ventricular contraction) after ablation was conducted in cs (coronary sinus).Emergency pci (percutaneous coronary intervention) with stenting with balloons was performed based on the diagnosis of lcx (left circumflex artery) occlusion.Patient outcome was improved.Lcx flow was recovered and maintained.Patient was followed up in hospital for pericarditis and will be discharged soon.The physician's opinion on the relationship between the event and the product was that the heat from ablating in the cs might have added to the lcx.The ablation was stopped several times due to the impedance monitoring, and the device was working as normal during the operation.There were no abnormalities observed before or while using the product.Device evaluation details: the device was returned to biosense webster (bwi) for evaluation.A visual inspection and revision of all features were performed following bwi procedures.Visual analysis revealed no damage or anomalies on the device.The device features were reviewed, and no issues were observed during the product investigation.A manufacturing record evaluation was performed for the finished device 31137563l number, and no internal action related to the complaint was found during the review.No malfunction was observed during the product analysis.The root cause of the adverse event remains unknown.There may have been other circumstances or issues that occurred during the use of the device that could not be replicated during the analysis.The instruction for use (ifu) states that careful catheter manipulation must be performed to avoid cardiac damage, perforation or tamponade.As part of biosense webster¿s quality process, all devices are manufactured, inspected, and released to approved specifications.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's reference number: (b)(4).
|
|
Search Alerts/Recalls
|
|