Catalog Number D128211
Device Problems Device Alarm System (1012); Obstruction of Flow (2423)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/20/2023
Event Type  malfunction  
Manufacturer Narrative
On 23-jan-2024, the bwi product analysis lab received the complaint device for evaluation.The product analysis has begun but is not completed at this time.When the investigational analysis has been completed, a supplemental 3500a report will be submitted.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster inc., or its employees that the report constitutes an admission that the product, biosense webster inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.# (b)(4).
 
Event Description
It was reported that a patient underwent an atrial fibrillation (afib) ablation procedure with a pentaray nav high-density mapping eco catheter and the device (including port, luer hub) was not irrigating.It was reported that during the operation, device (including port, luer hub) was not irrigating.A second device was used to complete the operation.There was no adverse event reported on patient.On 8-jan-2024, additional information was received indicating the issue occurred during use on the patient.The irrigation issue was suspected to be with the catheter.Bubble got detected after minutes of irrigation for few times.The unspecified bwi pump was switch from ¿low¿ to ¿high¿ flow during irrigation, but the flow was quite slow out of the catheter even when the pump was flushing.The correct settings were selected on the generator.
 
Manufacturer Narrative
It was reported that a patient underwent an atrial fibrillation (afib) ablation procedure with a pentaray nav high-density mapping eco catheter and the device (including port, luer hub) was not irrigating.It was reported that during the operation, device (including port, luer hub) was not irrigating.A second device was used to complete the operation.There was no adverse event reported on patient.Device evaluation details: the device was returned to biosense webster inc (bwi) for evaluation and the evaluation has been completed.A visual inspection and patency test of the returned device were performed in accordance with bwi procedures.Visual analysis of the returned device revealed that no damage or anomalies were observed on the device.A patency test was performed, and irrigation could not be performed, therefore, dissection was performed in the tip area and the irrigation tube was found folded, the root cause of the irrigation issue reported by the customer could be related to this failure.A manufacturing record evaluation was performed and no internal action related to the complaint was found during the review.The issue reported by the customer was confirmed.It should be noted that product failure is multifactorial.As part of biosense webster's quality process, all devices are manufactured, inspected, and released to approved specifications.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.# (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PENTARAY NAV HIGH-DENSITY MAPPING ECO CATHETER
Type of Device
CATHETER, INTRACARDIAC MAPPING, HIGH-DENSITY ARRAY
Manufacturer (Section D)
BIOSENSE WEBSTER INC
31 technology drive, suite 200
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
kate karberg
31 technology dr
irvine, CA 92618
3035526892
MDR Report Key18592986
MDR Text Key334735319
Report Number2029046-2024-00315
Device Sequence Number1
Product Code MTD
UDI-Device Identifier10846835012255
UDI-Public10846835012255
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K123837
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/28/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/28/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberD128211
Device Lot Number31113565L
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/23/2024
Is the Reporter a Health Professional? No
Date Manufacturer Received01/31/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured07/31/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
UNKNOWN GENERATOR; UNKNOWN IRRIGATION PUMP
-
-