Model Number MX9505
Device Problem Unable to Obtain Readings (1516)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/01/2024
Event Type  malfunction  
Event Description
It was reported that while preparing to use a pressure sensor to monitor central venous pressure, the monitor has no normal waveform after the pressure sensor is connected to the lead wire.At the same time, cannot adjust it to zero.The same problem occurs after replacing the lead wire multiple times.After replacing it, the display is normal.There was no patient involvement reported.
 
Manufacturer Narrative
B3: date of event is unknown, no information has been provided to date.Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.
 
Manufacturer Narrative
Device evaluation: one used, decontaminated device was returned for investigation.Visual inspection of the electrical board found one lead wire were was observed to be not fully soldered.The sample failed the electrical test.The complaint was confirmed.A review of the device history record (dhr) shows there were no observations or nonconformities recorded during manufacture to suggest an issue of this nature would occur with this lot of products.This issue will continue to be monitored and further actions taken accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MEDEX TRANSTAR PRESSURE TRANSDUCER
Type of Device
PRESSURE MONITORING|MEDEX TRANSTAR KITS
Manufacturer (Section D)
SMITHS HEALTHCARE MANUFACTURING S.A. DE C.V.
carretera miguel alemán km21.7
apodaca nuevo leon
MX 
Manufacturer Contact
reed covert
6000 nathan lane north
minneapolis, MN 55442
2247062300
MDR Report Key18602671
MDR Text Key334064415
Report Number9616567-2024-00019
Device Sequence Number1
Product Code DPT
UDI-Device Identifier10351688503992
UDI-Public(01)10351688503992(17)250810(10)4323152
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K942377
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date 03/20/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/29/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberMX9505
Device Catalogue NumberMX9505T
Device Lot Number4323152
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer01/11/2024
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/22/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/16/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-