Model Number 101967-931
Device Problem Imprecision (1307)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/05/2024
Event Type  malfunction  
Manufacturer Narrative
The manufacturer is currently performing investigation and the results will be provided in the supplemental report.
 
Event Description
On feb 05th 2024,senseonics was made aware of an incident where user experienced inaccuracies in sensor readings which led to early sensor removal.
 
Manufacturer Narrative
Based on the initial escalation analysis, a return material authorization was authorized for the sensor due to the deviation in the system performance from normal behavior.Although the sensor was not received, the dms data showed there was potential oxidation of the sensor's hydrogel.As part of resolution, the rma was authorized to offer the user a sensor replacement.B4.Date of this report updated to (b)(6) 2024.G3.Date received by manufacturer updated to (b)(6) 2024.H3.Device evaluated by manufacturer? yes.H6.Type of investigation updated to 10.H6.Investigation findings updated to 114.H6.Investigation conclusions updated to 4307.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVERSENSE SENSOR
Type of Device
EVERSENSE CONTINUOUS GLUCOSE MONITOR SYSTEM
Manufacturer (Section D)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20876 7005
Manufacturer (Section G)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20876 7005
Manufacturer Contact
vallikannu somasundaram
20451 seneca meadows parkway
germantown, MD 20876-7005
MDR Report Key18820714
MDR Text Key336772711
Report Number3009862700-2024-00045
Device Sequence Number1
Product Code QHJ
Combination Product (y/n)Y
Reporter Country CodeIS
PMA/PMN Number
P160048
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Consumer
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 04/29/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/01/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date02/16/2024
Device Model Number101967-931
Device Catalogue NumberFG-4500-31-302
Device Lot NumberWP09240
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/14/2024
Is the Reporter a Health Professional? No
Date Manufacturer Received04/29/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/21/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-