Catalog Number 311.430
Device Problem Device-Device Incompatibility (2919)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/21/2024
Event Type  malfunction  
Event Description
Device report from synthes reports an event in japan as follows: it was reported that on (b)(6) 2024, the patient underwent an unknown surgery treating the distal radius.It was confirmed that the patient had had bilateral fractures of the distal ends of the radius, and tcp products had been used bilaterally.A postoperative x-ray of the right side showed that the contralateral cortical bone was cracked where the cortex screw was inserted.The rotating part at the base of the handle did not move well, making it difficult to insert screws.It was difficult to attach the drill sleeve in question to locking holes and stability could not be obtained.When the drill sleeve was tightened strongly to stabilize it, it became difficult to remove from a plate.For the drill sleeve, it was difficult to attach to locking holes and stability could not be obtained.When it was tightened strongly to stabilize it, it became difficult to remove from a plate.The surgery was completed successfully with no surgical delay.Patient was listed as stable pc ((b)(4).) captures the left radius.Pc ((b)(4).) captures the right radius.Pc ((b)(4).) to capture the postoperative event on the right side.This report is for handle with quick coupling, small for (b)(4).
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Initial reporter is j&j company representative the investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: g1 h4 device history part# 311.430 lot # 2795013 manufacturing site: werk selzach logistik supplier: (b)(4) release to warehouse date: 24 oct 2011 expiration date: na a manufacturing record evaluation was performed for the finished article lot and no non-conformances were identified device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HANDLE WITH QUICK COUPLING, SMALL
Type of Device
BONE TAP
Manufacturer (Section D)
SYNTHES GMBH
eimattstrasse 3
oberdorf 4436
SZ  4436
Manufacturer (Section G)
SYNTHES BETTLACH GMBH
muracherstrasse 3
bettlach CO 2544
SZ   2544
Manufacturer Contact
kate karberg
1302 wright lane east
west chester, PA 19380
3035526892
MDR Report Key18869078
MDR Text Key337745293
Report Number8030965-2024-03424
Device Sequence Number1
Product Code HWX
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number311.430
Device Lot Number2795013
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/21/2024
Initial Date FDA Received03/08/2024
Supplement Dates Manufacturer Received05/09/2024
Supplement Dates FDA Received05/13/2024
Was Device Evaluated by Manufacturer? No
Date Device Manufactured10/24/2011
Is the Device Single Use? No
Type of Device Usage Unknown
Patient Sequence Number1
Treatment
LCP DRILL SLEEVE 2.4 W/SCAL-30 F/DRILL B; UNK - PLATES: TRAUMA; UNK - SCREWS: TRAUMA
-
-