Model Number 7122Q/58
Device Problems Failure to Capture (1081); Difficult to Fold, Unfold or Collapse (1254); Retraction Problem (1536)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/05/2024
Event Type  Injury  
Event Description
It was reported the patient presented for a post implant check in the hospital.Interrogation revealed the right ventricular lead exhibited a loss of capture.A lead revision was attempted; it was observed that the lead helix could not extend or retract normally.The lead was explanted and replaced.The patient was in stable condition.
 
Manufacturer Narrative
The reported events were helix mechanism issue and failure to capture.The reported event helix mechanism issue was confirmed.A complete lead was returned in one piece with a stylet inserted.The lead was returned with the helix extended and clogged with blood/tissue.X-ray inspection found the inner coil over torqued at the connector region consistent with procedure damage.X-ray examination of the helix mechanism found no anomalies or distortion of the helix that would have contributed to helix mechanism issue reported in the field.The reported event failure to capture was not confirmed.Electrical testing did not find any indication of conductor fractures or internal shorts.The cause of the reported event helix mechanism issue was isolated to blood/tissue in the helix region and over torque of the inner coil.The inner coil and helix were damaged during analysis.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DURATA STS OPTIM ACTIVE FIXATION, DF-4 CONNECTOR
Type of Device
Permanent defibrillator electrodes
Manufacturer (Section D)
ST. JUDE MEDICAL, INC.(CRM-SYLMAR)
15900 valley view court
sylmar CA 91342
Manufacturer (Section G)
ST. JUDE MEDICAL, INC.(CRM-SYLMAR)
15900 valley view court
sylmar CA 91342
Manufacturer Contact
richard williamson
15900 valley view court
sylmar, CA 91342
MDR Report Key18951095
MDR Text Key338258056
Report Number2017865-2024-35562
Device Sequence Number1
Product Code NVY
UDI-Device Identifier05414734503174
UDI-Public05414734503174
Combination Product (y/n)Y
Reporter Country CodeUS
PMA/PMN Number
P950022
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,User Facility,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 03/21/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/21/2024
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/31/2024
Device Model Number7122Q/58
Device Lot NumberA000109183
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received03/05/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/28/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
GALLANT.; QUARTET.; TENDRIL.
Patient Outcome(s) Required Intervention;
Patient Age81 YR
Patient SexMale
-
-