Catalog Number MP1000 CHINA |
Device Problem
Complete Blockage (1094)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 01/03/2024 |
Event Type
malfunction
|
Manufacturer Narrative
|
H.3.If a device evaluation and/or device history review is completed, a supplemental report will be filed.
|
|
Event Description
|
It was reported that bd maxplus needleless connector was occluded the following information was received by the initial reporter with the following verbatim: the patient was admitted to the hospital with a right rotator cuff injury, and during the course of an intravenous infusion given at 9:00 p.M.On (b)(6) 2024 it was noted that the fluid was not dripping; the infusion line was checked for any anomalies, and the drip was clear after a new needleless connector was given.
|
|
Manufacturer Narrative
|
Additional information: expiration date and device manufacture date added investigation results: no samples were received for investigation of (b)(4) , in which the customer has stated: ¿the fluid was not dripping¿.The product in use at the time is reported to be a mp1000 china from lot 23025311.No additional information was available to assist the investigation in this instance.The details of this feedback were forwarded to the manufacturing site for investigation, where a review of the production records for lot 23025311 did not identify any in-process testing failures or quality deviations which may have caused or contributed to a report of this nature.The root cause of the customer¿s experience could not be determined in this instance as no sample was received for investigation.Without a sample to examine it is not possible to determine whether a manufacturing defect could have caused or contributed to a report of this nature.Previous investigations have identified that certain designs of male luer can cause flow restriction or occlusion as they can grip onto the piston of the maxplus preventing its proper collapse.This can sometimes be resolved by disconnecting and reattaching the same luer connection which may reposition the luer against the piston and improve the flow, or alternatively by changing the connecting male luer.In this instance, without the complaint sample to examine it has not been possible to conclusively link this feedback to a specific failure mode; however, a review of the customer feedback database indicates that this is a rare occurrence with a small number of similar reports against the mp1000 china products in the past 12 months.
|
|
Event Description
|
No additional information.
|
|
Search Alerts/Recalls
|