H10: the catalog number identified in section d4 has not been cleared in the us but is similar to the fluency plus endovascular stent graft products that are cleared in the us.The pro code and 510 k number for the fluency plus endovascular stent graft products are identified in d2 and g4.H10: as the lot number for the device was provided, a review of the device history records is currently being performed.The device has been returned to the manufacturer for evaluation.However, photo was provided for review.The investigation of the reported event is currently underway.H10: d4: (expiry date: 08/2026).H11: section a: through f: the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
H10: the catalog number identified in section d4 has not been cleared in the us but is similar to the fluency plus endovascular stent graft products that are cleared in the us.The pro code and 510 k number for the fluency plus endovascular stent graft products are identified in d2 and g4.H10: manufacturing review: based on the information available it is not reasonably suggested that a manufacturing process may have caused or contributed to the reported issue.However, the lot history records of this lot were reviewed with special attention to the manufacturing and inspection of this product and the product was found to have met the specification prior to shipment.Investigation summary: the sample was returned for evaluation; the stent graft was found partially deployed and the outer sheath was fractured which leads to confirmed results.The condition of the returned sample depicts a device which failed during active usage as opposed to the reported information that a breakage happened when the package was opened.Also, a photo was provided which showed a fractured outer sheath of the device.Based on provided photos and the evaluation of the return sample, the investigation is closed with confirmed results for sheath fracture and partial deployment.A definite root cause for the reported event could not be determined.The intended use of the device in the femoral artery represent an off-label use.Labeling review: in reviewing the relevant labeling, it was found that the instructions for use sufficiently address the potential risks.Regarding preparation of the device the instructions for use states that "prior to loading the vascular system over a guide wire, both ports must be flushed with sterile saline (.).Flushing these lumens will also facilitate stent graft deployment.Continue until saline drips from the distal end of the delivery system".Regarding precautions, instructions for use states: "if excessive force is felt during stent graft deployment, do not force the delivery system.Remove the delivery system and replace with a new unit".Regarding accessories the instructions for use states: "a super stiff guide wire (0.035 in.) is advanced from a femoral artery puncture site.Use an introducer sheath for the implant procedure; the packaging pictograms indicate an introducer size of 9f and a 0.035" guidewire.Predilatation of the stenosis may be performed prior to stent graft deployment at the discretion of the physician".The fluency plus vascular stent graft is indicated for the treatment of atherosclerotic lesions in the iliac arteries.H10: d4 (expiry date: 08/2026), g3, h6 (device, method).H11: b5, h6 (patient, result, conclusion).H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|