Model Number 3852
Device Problem Material Rupture (1546)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/21/2024
Event Type  malfunction  
Event Description
It was reported that a balloon rupture occurred.The 75% stenosed target lesion was located in the moderately tortuous and calcified right coronary artery (rca).A 15mmx2.50mm wolverine coronary cutting balloon was selected for use.During percutaneous coronary intervention (pci), a non-boston scientific wire was used to cross the lesion and predilated with non-boston scientific balloon.However, the physician has decided to prepare calcified lesion using 15mmx2.50mm wolverine cutting balloon, but the balloon got burst upon first inflation at 6atm within 2-3 seconds.The device was removed successfully from the patient and the procedure was completed with another of the same device.There were no patient complications reported post procedure.
 
Manufacturer Narrative
E1.Initial reporter address 1: (b)(6) hospital.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WOLVERINE CORONARY CUTTING BALLOON MONORAIL
Type of Device
CATHETER, PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA), CUTTING/SCORING
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key19076677
MDR Text Key339810041
Report Number2124215-2024-20236
Device Sequence Number1
Product Code NWX
Combination Product (y/n)N
Reporter Country CodeIN
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,Company Representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 04/09/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/09/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number3852
Device Catalogue Number3852
Device Lot Number0032253804
Was Device Available for Evaluation? No
Date Manufacturer Received03/23/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/21/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient SexMale
Patient RaceAsian
-
-