ABBOTT IRELAND DIAGNOSTICS DIVISION ALINITY I FREE T4 REAGENT KIT; RADIOIMMUNOASSAY, FREE THYROXINE Back to Search Results
Catalog Number 07P70-30
Device Problem High Test Results (2457)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/25/2024
Event Type  malfunction  
Manufacturer Narrative
An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.All available patient information has been included.No additional patient details are available.
 
Event Description
The customer observed falsely elevated alinity i free t4 results.The following data was provided:.On (b)(6) 2024, for sid (b)(6) the initial result was >5.0 ng/l, repeated without dilution and obtained a result of 1.09 ng/dl (normal).On (b)(6) 2024, sid (b)(6) initial result was 4.17 ng/dl, repeated on a different module (b)(6) and the result was 0.90 ng/dl.On (b)(6) 2024, sid (b)(6) initial result was > 5.0 ng/l, repeated without dilution, generated a result of 2.30 ng/l.On (b)(6) 2024, sid (b)(6) -serum initial result was > 5.0 ng/l (b)(6), repeated without dilution, on another instrument (b)(6) which also generated a result > 5.0 ng/l.In a new sample, of plasma material, the result for sid (b)(6) -plasma was 1.22 ng/l.No impact to patient management was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALINITY I FREE T4 REAGENT KIT
Type of Device
RADIOIMMUNOASSAY, FREE THYROXINE
Manufacturer (Section D)
ABBOTT IRELAND DIAGNOSTICS DIVISION
lisnamuck
co. longford
longford N39E9 32
EI  N39E932
Manufacturer (Section G)
ABBOTT IRELAND DIAGNOSTICS DIVISION
lisnamuck
co. longford
longford N39E9 32
EI   N39E932
Manufacturer Contact
nicole jenne
max-planck-ring 2
post market surveillance
wiesbaden 65205
GM   65205
6122582960
MDR Report Key19121230
MDR Text Key340686934
Report Number3005094123-2024-00186
Device Sequence Number1
Product Code CEC
UDI-Device Identifier00380740121822
UDI-Public(01)00380740121822(17)240810(10)56159UD00
Combination Product (y/n)N
Reporter Country CodeBR
PMA/PMN Number
K173122
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 04/16/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number07P70-30
Device Lot Number56159UD00
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/26/2024
Initial Date FDA Received04/16/2024
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
ALNTY I PROCESSING MODU, 03R65-01, (B)(6)
-
-