Model Number 777F8
Device Problem Incorrect Measurement (1383)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/29/2024
Event Type  malfunction  
Event Description
It was reported that during use with the 777f8 swan-ganz catheter, there was noted discrepancies to have caused some recent mistrust in using the product and hemosphere.Upon arrival from the or, the swan-ganz catheter and hemosphere reading showed svo2 (venous oxygen saturation) 57 post calibration co 3.0 / ci 1.8, fick svo2 57, ci 3.0.They have been using this catheter and have had other reported discrepancies, they do not have specific data.No report of patient injury.Troubleshooting attempts were made by ensuring both hemospheres recalibrated with the most recent hgb and mixed venous saturation from the blood draw.They ensured accurate height and dry weight entered used in fick calculator.The swan-ganz catheter was confirmed in x-ray.The centimeter markings were confirmed with the marking in or.Adequate waveforms were on the monitor.The patient had stable core temperature and was not receiving any fluid boluses at the time.All cables were connected, secured, and not under any linens or pillows.The device is not available for return.Without the return of the product, it is not possible to determine if damages or defects exist on the product, nor can any manufacturing nonconformance, failure mode, root cause, or potential contributing factors be identified.No actions will be taken at this time.Complaint histories for all reported events are reviewed against trending control limits, and any excursions above the control limits are assessed and documented as part of this monthly review.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SWAN-GANZ CCOMBO V CCO/SVO2/CEDV/VIP THERMODILUTION CATHETER
Type of Device
SWAN-GANZ CCOMBO V
Manufacturer (Section D)
EDWARDS LIFESCIENCES, PR
state rd indus pk 402 km 1.4
anasco PR 00610
Manufacturer (Section G)
EDWARDS LIFESCIENCES, PR
state rd indus pk 402 km 1.4
anasco PR 00610
Manufacturer Contact
katheryn cespedes
1 edwards way
irvine, CA 92614
9492017706
MDR Report Key19130954
MDR Text Key340571747
Report Number2015691-2024-02940
Device Sequence Number1
Product Code DQE
UDI-Device Identifier00690103146554
UDI-Public(01)00690103146554(17)251008(11)231009(10)65370991
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K040287
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,User Facility
Reporter Occupation Nurse
Type of Report Initial
Report Date 04/17/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/18/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number777F8
Device Lot Number65370991
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received03/29/2024
Was Device Evaluated by Manufacturer? No
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-