Model Number 97714
Device Problems Overheating of Device (1437); Delayed Charge Time (2586); Charging Problem (2892); Communication or Transmission Problem (2896)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/01/2021
Event Type  malfunction  
Manufacturer Narrative
B3: date is approximate.Year is confirmed valid.Section d references the main component of the system.Other medical products in use during the event include: brand name restore; product id 37791 (serial: unknown); product type: 0213-recharger.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event Description
It was reported that information was received from a patient regarding an external device.The reason for call was patient reported they were having problems recharging their implanted neurostimulator (ins) and it was taking up to 8 hours to recharge it's been that way since 2021- 2022.Patient stated it was hard for them to get a good charge and had to reposition and sit still with no movement to get all coupling bars.Patient mentioned they would get one coupling bar or no coupling bars and by the time they would start to get a good charge the plate is hot.Patient mentioned the medtronic rep who reached out to them instructed patient to contact patient services for a new recharging equipment.Agent confirmed no messages or codes on the recharger.Agent instructed patient to inspect for damage; no visible damage to antenna.Agent confirmed patient's recharger is charging from the outlet.The issue was not resolved.An email was sent to the repair department to replace the antenna.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SURESCAN
Type of Device
STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR
Manufacturer (Section D)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer (Section G)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer Contact
glen belmer
7000 central avenue ne rcw215
minneapolis, MN 55432
6122713209
MDR Report Key19135427
MDR Text Key341301646
Report Number3004209178-2024-09334
Device Sequence Number1
Product Code LGW
UDI-Device Identifier00643169109483
UDI-Public00643169109483
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P840001
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Consumer
Reporter Occupation Other
Type of Report Initial
Report Date 04/18/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/18/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/14/2018
Device Model Number97714
Device Catalogue Number97714
Was Device Available for Evaluation? No
Date Manufacturer Received04/15/2024
Date Device Manufactured03/20/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
SEE H11...
Patient Age67 YR
Patient SexFemale
-
-