Model Number CD3361-40QC
Device Problems Over-Sensing (1438); Inappropriate/Inadequate Shock/Stimulation (1574)
Patient Problem Arrhythmia (1721)
Event Date 04/06/2024
Event Type  Injury  
Manufacturer Narrative
Further information was requested but not received.
 
Event Description
It was reported that the patient for follow up.An interrogation of the implantable cardioverter defibrillator revealed over-sensing that caused the device misclassify tachycardia episodes.This caused an episode of ventricular tachycardia (vt) to progress into ventricular fibrillation (vf) due to anti-tachycardia pacing that accelerated the rhythm.No patient symptoms or interventions were reported.Further information was requested but not received.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNIFY ASSURA ICD
Type of Device
No Match
Manufacturer (Section D)
ST. JUDE MEDICAL, INC.(CRM-SYLMAR)
15900 valley view court
sylmar CA 91342
Manufacturer (Section G)
ST. JUDE MEDICAL, INC.(CRM-SYLMAR)
15900 valley view court
sylmar CA 91342
Manufacturer Contact
richard williamson
15900 valley view court
sylmar, CA 91342
MDR Report Key19188098
MDR Text Key341114200
Report Number2017865-2024-39692
Device Sequence Number1
Product Code NIK
UDI-Device Identifier05414734508247
UDI-Public(01)05414734508247(10)P000118526(17)230331
Combination Product (y/n)N
Reporter Country CodeCA
PMA/PMN Number
P030054
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,User Facility
Reporter Occupation Nurse
Type of Report Initial
Report Date 04/25/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/25/2024
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/31/2023
Device Model NumberCD3361-40QC
Device Lot NumberP000118526
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received04/08/2024
Was Device Evaluated by Manufacturer? No
Date Device Manufactured03/05/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1