Model Number 3186
Device Problems Migration or Expulsion of Device (1395); Pocket Stimulation (1463); Device Operates Differently Than Expected (2913)
Patient Problems Discomfort (2330); Inadequate Pain Relief (2388)
Event Date 03/20/2014
Event Type  Injury  
Event Description
Device 1 of 3.Reference mfr report: 1627487-2014-15280, 1627487-2014-15281.It was reported the patient's leads migrated into the ipg pocket and the patient experienced uncomfortable pocket stimulation.Surgical intervention was undertaken on (b)(6) 2014 and the leads were explanted and replaced.The patient reported effective stimulation coverage postoperative and was no longer experiencing pocket stimulation.
 
Manufacturer Narrative
Sjm has limited information related to the patient's medical history and is unable to form an opinion as to the relevancy of the patient's history to the event reported.Sjm defers to the patient's physician regarding medical history.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OCTRODE
Type of Device
SCS LEAD
Manufacturer (Section D)
ST. JUDE MEDICAL - NEUROMODULATION
plano TX
Manufacturer Contact
toi milner
6901 preston rd.
plano, TX 75024
9723098107
MDR Report Key3764621
MDR Text Key4469251
Report Number1627487-2014-15279
Device Sequence Number1
Product Code GZB
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P010032
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Company Representative
Reporter Occupation Not Applicable
Type of Report Initial
Report Date 03/20/2014
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date10/01/2015
Device Model Number3186
Device Lot Number4294623
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 03/20/2014
Initial Date FDA Received04/11/2014
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured10/01/2013
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age76 YR
-
-