• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC SOFAMOR DANEK USA, INC INFUSE BONE GRAFT; FILLER, RECOMBINANT HUMAN BONE MORPHOGENETIC PROTEIN, COLLAGEN SCAFFOLD WITH MET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC SOFAMOR DANEK USA, INC INFUSE BONE GRAFT; FILLER, RECOMBINANT HUMAN BONE MORPHOGENETIC PROTEIN, COLLAGEN SCAFFOLD WITH MET Back to Search Results
Catalog Number 7510600
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Ossification (1428); Neuropathy (1983); Pain (1994)
Event Type  Injury  
Event Description
It was reported that the patient underwent an l4-s1 anterior lumbar fusion with l4-l5 and l5-s1 lumbar laminectomy using rhbmp-2/acs.Reportedly, sometime post-op, imaging studies revealed that the patient developed bony overgrowth at or near where the rhbmp-2/acs was implanted and nerve compression.The patient has experienced chronic pain and radiculitis.
 
Manufacturer Narrative
(b)(4).Neither the device nor applicable imaging study films or patient medical records were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.Products from multiple manufacturers were implanted/used during the procedure.Although it is unknown if any of the devices contributed to the reported event, we are filing this mdr for notification purposes.
 
Manufacturer Narrative
(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFUSE BONE GRAFT
Type of Device
FILLER, RECOMBINANT HUMAN BONE MORPHOGENETIC PROTEIN, COLLAGEN SCAFFOLD WITH MET
Manufacturer (Section D)
MEDTRONIC SOFAMOR DANEK USA, INC
4340 swinea rd
memphis TN 38118
Manufacturer (Section G)
MEDTRONIC SOFAMOR DANEK
1800 pyramid place
memphis TN 38132
Manufacturer Contact
huzefa mamoola
1800 pyramid place
memphis, TN 38132
9013963133
MDR Report Key4271008
MDR Text Key16781542
Report Number1030489-2014-04523
Device Sequence Number1
Product Code NEK
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P000058
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Consumer,consumer
Reporter Occupation Attorney
Type of Report Initial,Followup
Report Date 01/04/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/21/2014
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date04/01/2011
Device Catalogue Number7510600
Device Lot NumberM110808AAI
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received01/04/2016
Was Device Evaluated by Manufacturer? No
Date Device Manufactured04/22/2009
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-