Model Number M-4800-01
Device Problems Loss of Power (1475); Device Stops Intermittently (1599); Device Displays Incorrect Message (2591); Noise, Audible (3273)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 01/19/2015
Event Type  malfunction  
Event Description
It was reported that a patient underwent an atrial fibrillation ablation procedure with a carto 3 system and the procedure was delayed for 45 minutes and had to be cancelled due to noise issues.During the case, the physician experienced intermittent signal saturation from the carto that was then followed by complete loss of signal.Metal interference errors were also prominent during the case.The procedure was aborted after 45 minutes of troubleshooting.There was no patient consequence.The physician did not provide an opinion regarding the risk to the patient.We are reporting this event of procedural delay and cancellation because the patient experienced a delay of 45 minutes while under general anesthesia and after receiving a transeptal puncture.
 
Manufacturer Narrative
Concomitant products: thermocool catheter (lot# 17054105m) stockert generator (serial# (b)(4)) (b)(6).Manufacture¿s reference no.: (b)(4).The product has not been returned for analysis.The product investigation is pending.
 
Manufacturer Narrative
Manufacturer's ref no: (b)(4).It was reported that a patient underwent an ablation procedure with a carto 3 system and the procedure was delayed and had to be cancelled due to noise issues.During the case, the physician experienced intermittent signal saturation from the carto that was then followed by complete loss of signal.Metal interference errors were also prominent during the case.This event of procedural delay and cancellation was mdr reported because the patient experienced a delay of 45 minutes while under general anesthesia and after receiving a transeptal puncture.The hardware investigation revealed that the carto main card was faulty.The customer¿s patient interface unit (piu) and location pad (lp) were replaced; the noise issue was resolved.The system is ready for use.The customer complaint was confirmed.Dhr review was performed by the manufacturer and no anomalies were noted in manufacturing or servicing of this equipment.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CARTO® 3 SYSTEM
Type of Device
COMPUTER, DIAGNOSTIC, PROGRAMMABLE
Manufacturer (Section D)
BIOSENSE WEBSTER (ISRAEL) LTD.
4 hatnufah street
yokneam 2066 717
IS  2066717
Manufacturer (Section G)
BIOSENSE WEBSTER (ISRAEL) LTD.
4 hatnufah street
yokneam 2066 717
IS   2066717
Manufacturer Contact
jaime chavez
9098398483
MDR Report Key4485830
MDR Text Key17690336
Report Number3008203003-2015-00003
Device Sequence Number1
Product Code DQK
Combination Product (y/n)N
Reporter Country CodeAS
PMA/PMN Number
K133916
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/19/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberM-4800-01
Device Catalogue NumberFG540000
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 01/19/2015
Initial Date FDA Received02/04/2015
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received07/29/2015
Was Device Evaluated by Manufacturer? Yes
Type of Device Usage Reuse
Patient Sequence Number1
-
-