Literature articled received.This report is being filed after subsequent review of the following literature article: gauthier, l, et al (2014).Perioperative neurologic injury associated with rib-based distraction surgery.Spine deformity, 2, 481-488.(b)(4).There was a retrospective review of the children¿s spine study group database from 2004-2013.The researchers used the chi-squared test to compare the distributions of portions between diagnoses.The inclusion criteria were any rib-to-rib or spine-to-rib instrumentation.Growing rods without rib based attachments were excluded.A total of 524 patients were identified who were treated with rib-based distraction surgery.Nine neurologic injuries were identified in these patients (7 clinical and 2 neuro-monitoring alerts) for a neurologic injury rate of 1.7%.Using the classification for early-onset scoliosis, 8 patients were classified as congenital and 1 as neuromuscular.At the time of injury, the mean age was 4.1 +/- 2.2 years, the mean scoliosis was 66.3° +/- 21.9°, and the mean kyphosis was 43.5° +/- 36.9°.All of the injuries occurred at the time of initial implantation, with the exception of 1 patient in whom injury occurred during revision surgery.There were no injuries identified during routine lengthening surgery.There were no complete spinal cord injuries and most involved injury to the brachial plexus.Two patients counted as having a neurologic injury had changes in neuromonitoring only but no deficits existed on post-operative clinical exams.Of the other 7 with clinical injuries, only 2 had a neuromonitoring alert.Four patients required return to surgery and 1 needed intraoperative intervention.At the 4.2 years¿ follow-up, 7 of 9 patients had full resolution of symptoms and 2 patients had residual upper extremity weakness.This report refers to patient # 6.Patient 6 was 3 years, 4 months at the time of the event.Their primary diagnosis was congenital scoliosis with fused ribs.Patient 6¿s construct levels were: medial t2/3 pelvis; lateral t2/3-t8; convex t2/3 pelvis.Patient 6 experienced mild ipsilateral arm weakness due to first rib compression of lower trunk.The course of action was distraction release on lateral and medial device and inferolateral cradle device removed (postoperative day 1).The patient was listed as partially recovered.This is report 6 of 9 for (b)(4).This report is for an unknown vertical expandable prosthetic titanium rib (veptr) construct, unknown part#/lot#.
|
Gauthier, l, et al (2014).Perioperative neurologic injury associated with rib-based distraction surgery.Spine deformity, 2, 481-488.This report is for an unknown veptr/unknown quantity/unknown lot.The investigation could not be completed and no conclusion could be drawn, as no device was returned and no lot number for part number was provided.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|