Model Number 60-02-15
Device Problem Other (for use when an appropriate device code cannot be identified) (2203)
Patient Problem No Patient involvement (2648)
Event Date 03/23/2015
Event Type  malfunction  
Event Description
Sorin group deutschland received a report that the centrifugal pump system displayed an error message during setup.There was no patient involvement.
 
Manufacturer Narrative
Sorin group (b)(4) manufactures the sorin centrifugal pump system with tubing clamp.The incident occurred in (b)(6).This medwatch report is filled on behalf of sorin group (b)(4).Sorin group received a report that the centrifugal pump system displayed an error message during setup.There was no patient involvement.The investigation is ongoing.A follow-up report will be sent when the investigation is complete.
 
Manufacturer Narrative
Sorin group (b)(4) received a report that the centrifugal pump system displayed an error message during setup.There was no patient involvement.During evaluation of the involved device on site, a sorin group service representative was able to reproduce the reported issue and found a problem with the shaft angle encoder.The encoder was replaced and the unit was returned to service.A review of the device history record did not find any deviations or nonconformities related to the reported issue.No trend has been identified.Sorin group (b)(4) will continue to monitor the market for trends related to this issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SORIN CENTRIFUGAL PUMP SYSTEM WITH TUBING CLAMP
Type of Device
CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
SORIN GROUP DEUTSCHLAND
lindberghstr. 25
munich D8093 9
GM  D80939
Manufacturer (Section G)
SORIN GROUP DEUTSCHLAND
lindberghstr. 25
munich D 809 39
GM   D 80939
Manufacturer Contact
cheri voorhees, mgr.
14401 w. 65th way
arvada, CO 80004
3034676527
MDR Report Key4731476
MDR Text Key5741006
Report Number9611109-2015-00119
Device Sequence Number1
Product Code DWA
Combination Product (y/n)N
Reporter Country CodeFR
PMA/PMN Number
K032213
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,health professional
Reporter Occupation Unknown
Remedial Action Other
Type of Report Initial,Followup
Report Date 03/23/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/22/2015
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number60-02-15
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received07/27/2015
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured10/01/2009
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-