Catalog Number 532.001
Device Problems Power Conditioning Problem (1474); Physical Resistance (2578); Mechanical Jam (2983)
Patient Problem No Information (3190)
Event Type  malfunction  
Manufacturer Narrative
(b)(6).The actual device was returned for evaluation.Reliability engineering evaluated the device and observed that the device motor seized, jammed and was heavy moving.It was further reported that the motor had enough power, but was overheating and the ball bearings were worn.Therefore, the reported condition was confirmed.The assignable root cause was determined to be due to wear from normal use and servicing over time.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
It was reported from (b)(6) that during use, it was observed the rotational speed was lower than expected on the small battery drive device.During in-house engineering evaluation, it was observed that the device motor seized, jammed and was heavy moving.It was further reported that the motor had enough power but was overheating and the ball bearings were worn.It was not reported if the device was used in surgery, or if there was patient involvement.It was not reported if there were any delays in a surgical procedure or if a spare device was available.It was not reported if there were any injuries, medical intervention or prolonged hospitalization.The exact date of this event was unknown.All available information has been disclosed.If additional information should become available, a supplemental medwatch report will be submitted accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COLIBRI
Type of Device
INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED, MOTOR/ACCESS AND ATTACHMENT
Manufacturer (Section D)
DEPUY SYNTHES POWER TOOLS
hauptstrasse 24
waldenburg CH443 7
SZ  CH4437
Manufacturer (Section G)
DEPUY SYNTHES POWER TOOLS
hauptstrasse 24
waldenburg CH443 7
SZ   CH4437
Manufacturer Contact
linda plews
1302 wrights lane east
west chester, PA 19380
6107195000
MDR Report Key5017068
MDR Text Key24544306
Report Number3009450871-2015-13029
Device Sequence Number1
Product Code HWE
Combination Product (y/n)N
Reporter Country CodeIT
PMA/PMN Number
PEXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Report Date 12/17/2014
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/19/2015
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number532.001
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/02/2015
Date Manufacturer Received08/06/2015
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/30/2011
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N