MAUDE Adverse Event Report: PRODUCTOS PARA EL CUIDADO DE LA SALUD -9611590 INLAY PIGTAIL URETERAL STENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PRODUCTOS PARA EL CUIDADO DE LA SALUD -9611590 INLAY PIGTAIL URETERAL STENT Back to Search Results
Catalog Number 778626
Device Problems Fracture (1260); Out-Of-Box Failure (2311)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 08/05/2015
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete, a supplemental report will be filed.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event Description
It was reported that the stent was fractured when the package was opened.
 
Manufacturer Narrative
Received one used inlay ureteral stent.Visual inspection noted that one of the pigtails had cracked.No pieces of the stent appear to be missing.Further visual evaluation found that kidney end is broken in eyelet.The broken section was still attached to the stent; also it presents stress marks; like the stent was stressed beyond its tensile capabilities.Functional evaluation found no difficulty in the stent when the guidewire slipped through it.The stent dimensions were found within specification.The reported event is confirmed with the cause unknown.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use states the following: "improper handling technique can seriously weaken the stent.Acute bending or overstressing during placement could result in subsequent separation of the stent at the point of stress after a prolonged indwelling period.Exercise care.Tearing of the stent can be caused by sharp instruments.Care should be exercised when removing the stent from inner polybag so as not to cause tearing or fragmentation." the information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INLAY PIGTAIL URETERAL STENT
Type of Device
STENT
Manufacturer (Section D)
PRODUCTOS PARA EL CUIDADO DE LA SALUD -9611590
km. 7 carretera internacional
nogales, sonora 85621
MX  85621
Manufacturer (Section G)
PRODUCTOS PARA EL CUIDADO DE LA SALUD -9611590
km. 7 carretera internacional
nogales, sonora 85621
MX   85621
Manufacturer Contact
janna parks
8195 industrial blvd
covington, GA 30014
7707846100
MDR Report Key5049715
MDR Text Key25539651
Report Number1018233-2015-00331
Device Sequence Number1
Product Code FAD
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K983498
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,other
Reporter Occupation Health Professional
Type of Report Followup
Report Date 09/30/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/31/2019
Device Catalogue Number778626
Device Lot NumberNGYJ3767
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/30/2015
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received Not provided
Initial Date FDA Received09/02/2015
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received10/28/2015
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/11/2014
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-