Model Number 70104.4054
Device Problems Overheating of Device (1437); Improper or Incorrect Procedure or Method (2017)
Patient Problem No Patient Involvement (2645)
Event Date 01/26/2016
Event Type  malfunction  
Manufacturer Narrative
On 02/18/2016 10:03 am (gmt-5:00) added by (b)(6): (b)(4).A maquet field service technician was on site and investigated the unit.The technician troubles shot the device and figured out that the device overheated because the klixxon fuse triggered.The technician reset the klixxon fuse.The unit was tested for functionality and a diagnostic test was successfully performed.
 
Event Description
On 02/18/2016 09:54 am (gmt-5:00) added by (b)(6): it was reported that during preventive maintenance of the hcu40 the user drained the water too early which resulted in a overheating of the patient heater.Additional information: the incident occurred during preventive maintenance so there were no patient involved.(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MAQUET HCU30 DEVICE
Type of Device
CONTROLLER, TEMPERATURE, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
MAQUET CARDIOPULMONARY AG
rastatt
GM 
Manufacturer (Section G)
BERND RAKOW
maquet cardiopulmonary ag
kehler strasse 31
76437 rastatt
GM  
Manufacturer Contact
maquet cardiopulmonary ag
kehler strasse 31
76437 rastatt 
4972229321
MDR Report Key5447545
MDR Text Key39117146
Report Number8010762-2016-00096
Device Sequence Number1
Product Code DWC
Combination Product (y/n)N
Reporter Country CodeGM
PMA/PMN Number
K130300
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,foreign,health profe
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 01/26/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/19/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number70104.4054
Device Catalogue Number70104.4054
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/23/2015
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/01/2015
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-