Model Number G148
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Death (1802); Cardiac Tamponade (2226)
Event Date 04/21/2016
Event Type  Death  
Manufacturer Narrative
As no further information concerning this report is expected, our investigation is complete.This investigation will be updated should further information be provided.
 
Event Description
Boston scientific received information that the patient implanted with this cardiac resynchronization therapy defibrillator (crt-d) system passed away the morning after the implant procedure.The physician initially questioned tamponade; however the pericardial tap only drew off a limited amount of fluid, therefore the physician did not believe the procedure (i.E., lead placement, etc) caused the patient to decompensate, rather the patient had poor heart function.The field representative noted that the patient was in very poor health and placed on comfort care prior to the procedure.The field representative was unable to provide any further information.The products were not returned to boston scientific.Our records indicate they were buried with the patient.
 
Manufacturer Narrative
--.
 
Event Description
--.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INOGEN
Type of Device
IMPLANTABLE CHF GENERATOR
Manufacturer (Section D)
GUIDANT CRM CLONMEL IRELAND
guidant ireland
clonmel, tipperary ireland
Manufacturer (Section G)
GUIDANT CRM CLONMEL IRELAND
guidant ireland
clonmel, tipperary ireland
Manufacturer Contact
sonali vasekar
4100 hamline ave. n
st. paul, MN 
6515824786
MDR Report Key5653234
MDR Text Key45135985
Report Number2124215-2016-07999
Device Sequence Number1
Product Code NIK
UDI-Device Identifier00802526534591
UDI-Public(01)00802526534591(17)20170804
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 04/22/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/13/2016
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Expiration Date08/04/2017
Device Model NumberG148
Other Device ID NumberINOGEN X4 CRT-D
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Manufacturer Received04/22/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/04/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Death; Hospitalization; Life Threatening; Required Intervention;
Patient Age82 YR
-
-