MAUDE Adverse Event Report: OSCOR INC. MEDTRONIC REUSABLE EXTENSION CABLE; ELECTRODE CABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

OSCOR INC. MEDTRONIC REUSABLE EXTENSION CABLE; ELECTRODE CABLE Back to Search Results
Model Number 53912
Device Problem Connection Problem (2900)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 07/14/2016
Event Type  malfunction  
Manufacturer Narrative
The device was in use for treatment.The device was not returned for evaluation; as a result, the allegations against this cable cannot be confirmed.A review of the device history records could not be performed as the lot number of the device is unknown.As the device was not returned for analysis, the root cause of the failure could not be determined.Potential cause of this failure: insufficient strength of soldered joint.Since the separation between the cable wire and the soldered pin may cause a disruption of the cable function, a corrective and preventive action has been opened to address this failure.Per the cable inspection procedure, during in process inspection the cable is inspected 100% for continuity.During final inspection, each strand of the cable is checked for the correct colored part, overall length of the cable, cable checked for damage and insulation voids, verification that the silicone strain relief extends at least for a length of 2 cm outside the female connector, checked that the silicone strain relief fits the wire snugly, checks for strain relieves for damage and gaps, a pull test is done on each connector and pin and the cable is inspected again for continuity.The instructions for use (ifu) informs the user: for reusable cables only: the cables can be re-sterilized by oscor eto gas sterilization a maximum of two times.The directions for use inform the user to: first attach the proximal connector(s) to a pacemaker/analyzer or another extension cable while observing polarity indicated by the color.Then attach the distal connector(s) to the temporary lead connector or to another extension cable, again observing polarity by the color.The detachment of the connection should be done in the reverse order.Precautions include: do not connect any cable model to a/c power source; connection of exposed pins to a/c power source may pose a risk of serious injury or death.Extension cables are not intended for use with apnea monitors.
 
Event Description
The customer reported this cable was affiliated with temporary pacing box model 5391; the box was being cleaned after a patient with a temporary pacing wire received a permanent pacemaker.When the nurse was cleaning the box, she wiped along the cable and the wire broke free from the black connector; it was reported she did not physically witness the breakage.While the box and cable were in use, there were no witnessed dropped beats or loss of capture to indicate that there was any break prior to her cleaning the cable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MEDTRONIC REUSABLE EXTENSION CABLE
Type of Device
ELECTRODE CABLE
Manufacturer (Section D)
OSCOR INC.
3816 desoto blvd.
palm harbor FL 34683 1618
Manufacturer (Section G)
OSCOR INC.
3816 desoto blvd.
palm harbor FL 34683 1618
Manufacturer Contact
dorit segal
3816 desoto blvd.
palm harbor, FL 34683-1618
7279372511
MDR Report Key5872828
MDR Text Key52092458
Report Number1035166-2016-00142
Device Sequence Number1
Product Code IKD
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K070926
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,health profession
Reporter Occupation Other
Type of Report Initial
Report Date 07/18/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Nurse
Device Model Number53912
Device Catalogue Number53912
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 07/18/2016
Initial Date FDA Received08/12/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-