• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: INTEGRA YORK, PA INC. UL PRO FUSED HEADLIGHT CABLE 9FT, 275CM; CABLES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INTEGRA YORK, PA INC. UL PRO FUSED HEADLIGHT CABLE 9FT, 275CM; CABLES Back to Search Results
Catalog Number 001388LX9
Device Problem Thermal Decomposition of Device (1071)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 10/17/2016
Event Type  malfunction  
Manufacturer Narrative
To date the device involved in the reported incident has not been received for evaluation.An investigation has been initiated based on the reported information.
 
Event Description
Customer initially reports that during surgey the light went dim.They discovered the inside of the lightsource end-fitting had burned/melted.On (b)(6) 2016 customer reports an anterior lumbar interbody fusion was being performed.Device in use 25 minutes before issue occurred.No harm to anyone.
 
Manufacturer Narrative
On 11/18/2016 integra investigation completed.Method: failure analysis, device history evaluation.Results: failure analysis: the cable was returned in used condition with damage to lens on the light source.The damage on the lens has occurred from too much heat.Device history evaluation: nonconforming product report / nonconforming material report history: none.Variance authorization / deviation history: none.Engineering change order / manufacturing change order history: none.Corrective action preventive action history: none.Health hazard evaluation history: none.Conclusion: without have the light source, it cannot be conclusively determined why the light source generated enough heat to damage the cable lens.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UL PRO FUSED HEADLIGHT CABLE 9FT, 275CM
Type of Device
CABLES
Manufacturer (Section D)
INTEGRA YORK, PA INC.
589 davies drive
589 davies drive
york PA 17402
Manufacturer (Section G)
INTEGRA YORK, PA INC.
589 davies drive
york PA 17402
Manufacturer Contact
sandra lee
311 enterprise drive
plainsboro, NJ 08536
6099362393
MDR Report Key6099025
MDR Text Key59741022
Report Number2523190-2016-00183
Device Sequence Number1
Product Code FST
Combination Product (y/n)N
PMA/PMN Number
K071218
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type user facility
Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date 10/18/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/14/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number001388LX9
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/14/2016
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/18/2016
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age45 YR
-
-