• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: B.BRAUN SURGICAL SA DAFILON BLUE 5/0 (1) 45CM DS19 (M); SUTURES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

B.BRAUN SURGICAL SA DAFILON BLUE 5/0 (1) 45CM DS19 (M); SUTURES Back to Search Results
Model Number C0933198
Device Problem Crack (1135)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Evaluation on-going.Device not returned.
 
Event Description
(b)(6).It is reported that the thread cracks easily near the needle.
 
Manufacturer Narrative
Samples received: 1 open pouch.Analysis and results: there are no previous complaints of this code batch.Manufactured (b)(4) units of this code batch.There are (b)(4) units in stock.Received one open and used sample with the thread broken near the needle attachment (approximately 1 cm to the needle attachment).Without any closed samples an analysis can not be performed in order to make a decision.Twelve units of stock for analysis was requested.Tested the knot pull tensile strength of the samples of stock and the results fulfill the oem requirements.Tested the needle attachment of the samples of stock and the results fulfill the oem requirements.Reviewed the batch manufacturing record, this product had a normal process and the results during the process fulfill the oem requirements.Remarks: "when working with suture materials great care should be taken to ensure that the use of surgical instruments, such as forceps and needle holders, do not cause any crushing or crimping damage to the suture material".Final conclusion: although the results of the samples of stock fulfill the oem specifications, note of this incident is taken in order to assess if new or additional actions are needed.Corrective/preventive actions: according to our internal procedures, there is no need to establish corrective or preventive actions.Nevertheless, this complaint is recorded for trending analysis to assess if actions are needed in the future.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DAFILON BLUE 5/0 (1) 45CM DS19 (M)
Type of Device
SUTURES
Manufacturer (Section D)
B.BRAUN SURGICAL SA
121 carretera de terrassa
rubi, barcelona 08191
SP  08191
Manufacturer (Section G)
B.BRAUN SURGICAL SA
121 carretera de terrassa
rubi, barcelona 08191
SP   08191
Manufacturer Contact
nicole broyles
615 lambert pointe drive
hazelwood, MO 63042
3145515988
MDR Report Key6139945
MDR Text Key61310152
Report Number2916714-2016-00990
Device Sequence Number1
Product Code GAR
Combination Product (y/n)N
Reporter Country CodeGM
PMA/PMN Number
K151165
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 02/01/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/01/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/01/2021
Device Model NumberC0933198
Device Catalogue NumberC0933198
Device Lot Number616136V004
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Distributor Facility Aware Date11/17/2016
Date Manufacturer Received01/23/2017
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-