SMITHS MEDICAL ASD, INC. PORTEX® PEDIATRIC DISPOSABLE ANESTHESIA BREATHING CIRCUITS; CIRCUIT, BREATHING (W CONNECTOR, ADAPTOR, Y PIECE) Back to Search Results
Catalog Number C37101678D-NL
Device Problems Disconnection (1171); Loose or Intermittent Connection (1371)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 11/29/2016
Event Type  malfunction  
Manufacturer Narrative
Smiths medical has received the sample device.A full evaluation is anticipated, but not yet begun as the device is currently in transit to the investigation site.Smiths medical will file a follow-up report detailing the results of the evaluation once it is completed.(b)(4).
 
Event Description
It was reported that at the beginning of the procedure while performing induction, the breathing circuit disconnected between the elbow and the y piece of the mask during holding of the mask.It was reported that a leak test was performed prior to use.There were no adverse health outcomes reported.
 
Manufacturer Narrative
One device was returned for evaluation.Visual inspection found that the elbow and y-connector were not disconnected.Functional testing involved a force test and found the device met with iso specifications and passed the force test.A review of the testing and inspection documents was performed and found to be adequate.A review of the manufacturing process was performed with a similar part (same process procedures, process controls, product tests, line equipment, process flow, and components) and found no disconnections between elbow and the y-connector.Based on the evidence, the root cause was unable to be confirmed as the device met manufacturing specification.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PORTEX® PEDIATRIC DISPOSABLE ANESTHESIA BREATHING CIRCUITS
Type of Device
CIRCUIT, BREATHING (W CONNECTOR, ADAPTOR, Y PIECE)
Manufacturer (Section D)
SMITHS MEDICAL ASD, INC.
6000 nathan lane north
minneapolis MN 55442
Manufacturer (Section G)
SMITHS HEALTHCARE MFG
s.a. de c.v. ave, calidad no.
parque industrial internaciona
tijuana, b.c. 22425
MX   22425
Manufacturer Contact
lisa perz
6000 nathan lane north
minneapolis, MN 55442
7633833074
MDR Report Key6200960
MDR Text Key63193524
Report Number3012307300-2016-00586
Device Sequence Number1
Product Code CAI
Combination Product (y/n)N
Reporter Country CodeCA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,u
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 08/14/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/22/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Respiratory Therapist
Device Expiration Date08/28/2019
Device Catalogue NumberC37101678D-NL
Device Lot Number3259243
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/30/2016
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Date Manufacturer Received07/18/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured08/20/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-