• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC NAVIGATION, INC. (LOUISVILLE) STEALTHSTATION S7 SYSTEM; NEUROLOGICAL STEREOTAXIC INSTRUMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC NAVIGATION, INC. (LOUISVILLE) STEALTHSTATION S7 SYSTEM; NEUROLOGICAL STEREOTAXIC INSTRUMENT Back to Search Results
Model Number S7
Device Problems Unintended Arm Motion (1033); Unintended Movement (3026)
Patient Problem No Patient Involvement (2645)
Event Date 01/03/2017
Event Type  malfunction  
Manufacturer Narrative
No patient information provided as no patient was involved in this concern.Return requested.Replacement articulating arm shipped to site 01/04/2017.No parts have been received by manufacturer for analysis.Part not received by manufacturer.
 
Event Description
A medtronic representative reported a site navigation system articulating arm that would not tighten properly.No further details regarding the damage, or how it occurred, were provided.There was no patient present when this issue was identified.
 
Manufacturer Narrative
The articulating arm was returned to the manufacturer for analysis.Investigation found that the articulating arm is very worn with many nicks and scratches on every surface.Oxidation is visible in the joints.The joints remain stiff when the handle has been released.The arm failed the articulating arm force test wi-n-22-01.The arm should withstand a downward force up to 14 lbs but failed at 3 lbs.The arm should also withstand a sideward force up to 10 lbs but failed at 4 lbs.The hardware investigation found that reported event was related to a mechanical failure; root cause reported as malfunction, will not tighten.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STEALTHSTATION S7 SYSTEM
Type of Device
NEUROLOGICAL STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
MEDTRONIC NAVIGATION, INC. (LOUISVILLE)
826 coal creek circle
louisville CO 80027
Manufacturer (Section G)
MEDTRONIC NAVIGATION, INC. (LOUISVILLE)
826 coal creek circle
louisville CO 80027
Manufacturer Contact
oksana ditolla
826 coal creek circle
louisville, CO 80027-9710
7208902187
MDR Report Key6265650
MDR Text Key65346498
Report Number1723170-2017-00236
Device Sequence Number1
Product Code HAW
UDI-Device Identifier00613994450944
UDI-Public00613994450944
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K050438
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Medical Equipment Company Technician/Representative
Type of Report Initial,Followup
Report Date 03/03/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberS7
Device Catalogue Number9733856
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/08/2017
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 01/03/2017
Initial Date FDA Received01/19/2017
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received03/03/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/08/2011
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-