Catalog Number AK-05501
Device Problem Bent (1059)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/31/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The facility has communicated that the device is not available for evaluation.The manufacturer will continue to monitor and trend related events.
 
Event Description
The touhy needle tip crimps over as it hits bone or hard cartilage preventing passage of the catheter.The patient's condition was reported as fine.
 
Manufacturer Narrative
(b)(4).A device history record review was performed based upon a lot numbers provided by the customer.A device history record review was performed on the epidural needle with no relevant findings.A corrective action is not required at this time as the potential cause of the needle tip bending could not be determined based upon the information provided and without a sample.Complaint verification testing could not be performed as no sample was returned for analysis.A device history record review was performed based upon a lot numbers provided by the customer.A device history record review was performed on the epidural needle with no evidence to suggest a manufacturing related cause.Therefore, the potential cause of the needle bending could not be determined based upon the information provided and without a sample.
 
Event Description
The touhy needle tip crimps over as it hits bone or hard cartilage preventing passage of the catheter.The patient's condition was reported as fine.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EPIDURAL CATHETERIZATION KIT: 19 GA
Type of Device
ANESTHESIA CONDUCTION KIT
Manufacturer (Section D)
ARROW INTERNATIONAL INC.
reading PA
Manufacturer (Section G)
ARROW INTERNATIONAL INC.
312 commerce place
asheboro NC 27203
Manufacturer Contact
jasmine brown
3015 carrington mill blvd
morrisville, NC 27560
9193614124
MDR Report Key6368269
MDR Text Key68760862
Report Number1036844-2017-00077
Device Sequence Number1
Product Code CAZ
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 02/01/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberAK-05501
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/01/2017
Initial Date FDA Received03/01/2017
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received03/27/2017
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-