• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: PENUMBRA, INC. LANTERN DELIVERY MICROCATHETER; DQY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PENUMBRA, INC. LANTERN DELIVERY MICROCATHETER; DQY Back to Search Results
Catalog Number PXSLIMLAN135T45
Device Problems Kinked (1339); Device Handling Problem (3265)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 04/27/2017
Event Type  malfunction  
Manufacturer Narrative
This device is available for return.A follow up mdr will be submitted upon completion of the device investigation.
 
Event Description
The patient was undergoing a coil embolization procedure using a lantern delivery microcatheters (lantern).During the procedure, the physician successfully deployed and detached three ruby coils in the target vessel using a lantern.The physician then inadvertently kinked the lantern near the hub and noticed it when trying to flush the lantern with saline.Therefore, the lantern was removed and the procedure was successfully completed using a new lantern.There was no report of an adverse effect to the patient.
 
Manufacturer Narrative
The lantern delivery microcatheters (lantern) was fractured approximately 7.0 cm from the proximal hub.The distal tip of the microcatheter had multiple bends at its end.Evaluation of the returned lantern revealed that the microcatheter was fractured near the proximal hub.If the microcatheter is forcefully manipulated during use, this type of damage is likely to occur.Further evaluation revealed multiple bends on the distal tip of the catheter.This damage is likely from the lantern remaining in tortuous anatomy during the procedure.Penumbra catheters are inspected during in-process inspection and during quality inspection after manufacturing.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LANTERN DELIVERY MICROCATHETER
Type of Device
DQY
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
Manufacturer Contact
veronica farris
one penumbra place
alameda, CA 94502
5107483200
MDR Report Key6587951
MDR Text Key75871966
Report Number3005168196-2017-00802
Device Sequence Number1
Product Code DQY
UDI-Device Identifier00814548016658
UDI-Public00814548016658
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K152840
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 04/27/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Physician
Device Expiration Date06/29/2019
Device Catalogue NumberPXSLIMLAN135T45
Device Lot NumberF70378
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/03/2017
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 04/27/2017
Initial Date FDA Received05/24/2017
Supplement Dates Manufacturer Received08/09/2017
Supplement Dates FDA Received09/11/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured06/29/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age54 YR
-
-