Model Number MMT-723NAS
Device Problems Device Displays Incorrect Message (2591); Electromagnetic Compatibility Problem (2927)
Patient Problem Hyperglycemia (1905)
Event Date 07/13/2013
Event Type  malfunction  
Manufacturer Narrative
The insulin pump passed displacement test, rewind and basic occlusion test.No motor error alarm noted.The insulin pump was unable to prime during prime test due to faulty force sensor resistor (gold).Analysis was unable to perform the occlusion test and excessive no delivery test due to prime/fill anomaly.Motor passed motor test.The pump had a scratched display window.Note: this is a remediation mdr.Medtronic diabetes implemented revised mdr reportability criteria effective on july 1, 2014.Subsequently, medtronic diabetes conducted a one year retrospective review of complaints.This event was retrospectively identified to be reportable based on the revised mdr reportability criteria.
 
Event Description
The customer reported via phone call that the insulin pump had a motor error alarm.The insulin pump was exposed to magnetic field.The blood glucose at the time of the incident was 395 mg/dl.Troubleshooting was not able to resolve the issue.The device was returned for analysis.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PARADIGM REAL-TIME REVEL INSULIN INFUSION PUMP
Type of Device
INSULIN INFUSION PUMP / SENSOR AUGMENTED
Manufacturer (Section D)
MEDTRONIC PUERTO RICO OPERATIONS CO.
ceiba norte ind. park #50
road 31 km 24.4
juncos PR 00777 3869
Manufacturer (Section G)
MEDTRONIC PUERTO RICO OPERATIONS CO.
ceiba norte ind. park #50
road 31 km 24.4
juncos PR 00777 3869
Manufacturer Contact
gerwin de graaff
18000 devonshire street
northridge, CA 91325-1219
8185764805
MDR Report Key6708038
MDR Text Key79936177
Report Number3004209178-2017-61404
Device Sequence Number1
Product Code OYC
Combination Product (y/n)N
PMA/PMN Number
P980022
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation Patient
Type of Report Initial
Report Date 07/13/2013
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Model NumberMMT-723NAS
Device Catalogue NumberMMT-723NAS
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/25/2013
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 07/13/2013
Initial Date FDA Received07/12/2017
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age64 YR
Patient Weight10
-
-