Model Number N/A
Device Problems Deflation Problem (1149); Device Operates Differently Than Expected (2913)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 06/13/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The event is currently under investigation.A follow-up report will be submitted upon receipt of additional information or completion of the investigation.
 
Event Description
It was reported that during hysterosalpingography procedure, the physician used a cook silicone balloon hysterosalpingography injection catheter.It was further reported that the balloon inflated completely, however it failed to deflate.The physician completed the intended procedure.No unintended section of the device remained inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
 
Manufacturer Narrative
Investigation ¿ evaluation: two cook silicone balloon hysterosalpingography injection catheters were returned for evaluation.Also returned was one unknown device with lot number 130791 and reference number (b)(4) in a sealed package.A functional test was performed on the two cook devices.Both devices inflated properly.When deflating the balloons one balloon deflated fine with no issues.The plunger on this balloon measured 2 mm past the connector.The other balloon took more pressure to deflate the balloon.The plunger on this balloon measured 3 mm past the connector.A definitive root cause for the deflation issue was not able to be determined at.This time.There is no indication that a design or process related failure mode contributed to this event.A review of production and quality documentation did not identify any specific issues with current manufacturing or quality controls that may have contributed to this incident.The device history record was reviewed and no non-conformances were noted.A review of complaint history for this product/lot number combination revealed there are no other complaints associated with lot number 7692821.Based on the provided information a definitive root cause cannot be established at this time.Measures have been initiated to address this failure mode.Per the quality engineering risk assessment, no further action is required.Cook medical has notified the appropriate personnel and will continue to monitor this device via the complaints database for similar complaints.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COOK SILICONE BALLOON HYSTEROSALPINGOGRAPHY INJECTION CATHETER
Type of Device
HES INSUFFLATOR-CARBON DIOXIDE, URETOTUBAL (AND ACCESSORIES)
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer Contact
larry pool
750 daniels way
bloomington, IN 47404
8123392235
MDR Report Key6716809
MDR Text Key80144843
Report Number1820334-2017-01597
Device Sequence Number1
Product Code HES
UDI-Device Identifier00827002171473
UDI-Public(01)00827002171473(17)200221(10)7692821
Combination Product (y/n)N
Reporter Country CodeIT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,foreign,health pr
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 09/29/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue NumberJ-CHSG-503000
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 06/20/2017
Initial Date FDA Received07/17/2017
Supplement Dates Manufacturer Received09/27/2017
Supplement Dates FDA Received09/29/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/21/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-