• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC HEART VALVES DIVISION FREESTYLE AORTIC ROOT BIOPROSTHESIS; HEART-VALVE, NON-ALLOGRAFT TISSUE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC HEART VALVES DIVISION FREESTYLE AORTIC ROOT BIOPROSTHESIS; HEART-VALVE, NON-ALLOGRAFT TISSUE Back to Search Results
Model Number FR995
Device Problems Material Rupture (1546); Material Perforation (2205)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 06/26/2017
Event Type  Injury  
Manufacturer Narrative
Without the return of the product, no definitive conclusion can be made regarding the clinical observation.
 
Event Description
Medtronic received information that 5 years 6 months post implant of this aortic bioprosthetic valve, the device had a leaflet tear and leaflet perforation.The physician excised the valve leaflets, left the body of the valve in place, and implanted a new valve inside of the existing device.No other adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FREESTYLE AORTIC ROOT BIOPROSTHESIS
Type of Device
HEART-VALVE, NON-ALLOGRAFT TISSUE
Manufacturer (Section D)
MEDTRONIC HEART VALVES DIVISION
1851 e deere ave
santa ana CA 92705
Manufacturer (Section G)
MEDTRONIC HEART VALVES DIVISION
1851 e deere ave
santa ana CA 92705
Manufacturer Contact
paula bixby
8200 coral sea street ne
mounds view, MN 55112
7635055378
MDR Report Key6772401
MDR Text Key82003802
Report Number2025587-2017-01329
Device Sequence Number1
Product Code LWR
UDI-Device Identifier00643169008137
UDI-Public00643169008137
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P970031
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial
Report Date 07/13/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/07/2017
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/07/2016
Device Model NumberFR995
Device Catalogue NumberFR995-27
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received07/13/2017
Was Device Evaluated by Manufacturer? No
Date Device Manufactured08/29/2011
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age60 YR
-
-