MICROMAR INDUSTRIA E COMERCIO LTDA EASYDRILL PERFORATOR; DRILLS, BURRS, TREPHINES & ACCESSORIES (COMPOUND, POWERED)
|
Back to Search Results |
|
Model Number DM0010FAA |
Device Problem
Device Remains Activated (1525)
|
Patient Problem
Perforation (2001)
|
Event Date 08/03/2017 |
Event Type
Injury
|
Manufacturer Narrative
|
Report inconclusive.No evaluation was performed, as the device was not returned.If the device is returned in the future, product analysis may be performed.This dm0010faa perforator with lot number 051/17 was manufactured by micromar.Multiple warnings are included in the easydrill cranial perforator ifu manual including: it is essential to keep the drill perpendicular (90°) at the predetermined point of the skull to be drilled, as an excessive deviation from perpendicularity may cause the product to fail and lead to serious patient injury.Select a drill bit suitable for the bone thickness.This prevents the drill from tearing the bone or brain tissue (similar effect when the bit is not positioned at 90°).If the components of the easydrill cranial perforator become loose during trephination, discontinue use.The drill can cut or tear the dura mater when it unlocks.Check some conditions before performing the procedure, such as the existence of adhering dura mater or other anomalies adjacent to the drilling site.We will continue to monitor this complaint type for trends.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
It was reported by the sales representative that the surgeon was drilling burr holes and experienced a dural tear.The neuro resident reported that he felt a sort of a wobbling sensation as he hit the inner table, so he let off the pedal for a moment.When he re-engaged the pedal fully and put pressure on the motor, the tool pushed through the shelf and hit the dura.According to the resident, it did not hit the brain directly, but caused a slight dural tear.The attending neurosurgeon, used gelfoam in the burr hole for hemostasis and moved forward with only a two or three minute delay.It was reported that there was no additional impact to the case.On follow up, it was reported the event occurred during the second burr hole.The first burr hole was made without complications.The patient was recovering from surgery as per normal protocols.The surgical site was the frontal/temporal bone and there were no specific indications of bone pathologies.
|
|
Search Alerts/Recalls
|
|
|