Catalog Number 2794
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Pulmonary Embolism (1498)
Event Date 11/04/2017
Event Type  Injury  
Manufacturer Narrative
Pt weight, ethnicity and race information was not supplied by reporter.Although pulmonary embolism occurs at a known rate postoperatively following joint replacement surgery, including knee arthroplasty, this was the 4th pulmonary embolism event reported to 3m from this study.This seems to be a slightly higher prevalence rate than expected but we do not know if it is statistically significant.3m contacted the study investigators to obtain additional patient details regarding operative duration, patient comorbidities and medical history.No additional information has been received to date.(b)(4).There was no conclusive evidence that the occurrence of a pulmonary embolism was related to the use of 3m coban 2 lite layer compression system post total knee arthroplasty.3m will continue to monitor complaints and trends for this type of report.
 
Event Description
An independent study investigator reported coban 2 lite layer compression system was applied to a (b)(6) female patient following a total knee arthroplasty.The patient experienced chest pain and shortness of breath on post op day 12.The patient was hospitalized and a ct scan confirmed the patient experienced a pulmonary embolism.
 
Manufacturer Narrative
3m received a formal letter from the university of (b)(6) regarding their investigation of the four pulmonary embolisms that occurred within the investigator-initiated research study entitled "the use of 3m¿ coban¿ 2 lite layer compression system post-total knee arthroplasty".The university (b)(6) consulted with two independent content experts to investigate the etiology of the pulmonary embolisms and to determine whether they were related to the study intervention, i.E., the 3m¿ coban¿ 2 lite layer compression system.In brief, the independent content experts reached consensus that the four pes were likely unrelated to the study intervention 3m¿ coban¿ 2 lite layer compression system.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COBAN 2 LITE LAYER COMPRESSION SYSTEM
Type of Device
COBAN 2 LITE LAYER COMPRESSION SYSTEM
Manufacturer (Section D)
3M HEALTH CARE
2510 conway ave
st. paul MN 55144
Manufacturer (Section G)
MANUFACTURING MEDICAL DEVICES
edisonstrasse 6
d-59157
kamen,
GM  
Manufacturer Contact
karen krenik, bsn
3m center building 275-5w-06
2510 conway ave
st. paul, MN 55144
6517333091
MDR Report Key7089114
MDR Text Key94071820
Report Number2110898-2017-00146
Device Sequence Number1
Product Code FQM
Combination Product (y/n)N
Reporter Country CodeCA
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,s
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 03/27/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue Number2794
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 11/07/2017
Initial Date FDA Received12/06/2017
Supplement Dates Manufacturer Received11/07/2017
Supplement Dates FDA Received03/27/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Other;
Patient Age55 YR
-
-