Catalog Number JC-05400-LB |
Device Problem
Physical Resistance (2578)
|
Patient Problem
Headache, Lumbar Puncture (2186)
|
Event Date 12/12/2017 |
Event Type
malfunction
|
Manufacturer Narrative
|
(b)(4).The device has not been returned for investigation at this time.Teleflex will continue to monitor and trend related events.
|
|
Event Description
|
It was reported that the new needle tuohy, the tip has less curvature than before and as a consequence 18 patients suffered wet needling, the epidural administration broke the ligament of dura mater, during the two last months.Patient complications: strong headaches, which can become chronic.It was reported that the patients are currently doing fine.
|
|
Manufacturer Narrative
|
(b)(4).A device history record review was performed on the epidural needle with no relevant findings.The customer reported the tip of the new epidural needle (spectra) in the kit has less curvature than the old needle (pajunk).The customer returned one new epidural needle from a kit with the same lot # as reported on the complaint (b)(4).No actual complaint sample was received.The customer also returned one pajunk needle as well.The returned needle was visually examined with and without magnification.The needle appears typical with no defects or anomalies observed.The needle tips of both the spectra and pajunk needles were compared microscopically.The curvature of both tips looked the same (b)(4).A design history review was performed for part rz-05400-006 as a part of this complaint investigation.Per (b)(4), (closed 31-jul-2015) a new part # was created (rz-05400-006) was created to replace part # kz-05400-006.And the supplier spectra would replace pajunk.Per the manufacturing site (zdar), the new needle was qualified in accordance with bs (b)(4) (specification for sterile epidural catheters and introducer needles for single other remarks: use) and have the same design as the originally used epidural needle from pajunk.The curvature angle is the same and no change to the ifu was done.Also during the needle qualification, the needle rz-05400-006 was clinically evaluated and found acceptable.There were no changes announced after switch to production lifecycle.The ifu for this kit, cz-05400-108a; rev.02, was reviewed as a part of this complaint investigation.The ifu suggests "prep puncture site and drape to form sterile field.Perform skin wheal using desired needle.Make a small skin nick of approximately 2 mm at insertion site to help facilitate epidural needle introduction.Where provided, the attachable epidural needle winged hub may be assembled to needle prior to insertion.Winged hub can be attached to needle by sliding hub over needle cannula (refer to fig.1) and pushing it firmly onto hub of needle (refer to fig.2).Precaution: winged hub should not be removed after being firmly positioned.This hub is designed for use with needle in this product only.Orient bevel and insert epidural needle.Advance forward until tip is felt embedded in ligamentum flavum.Remove stylet from epidural need le.To aid in determination of location of the epidural space, use hanging drop method or attach appropriate syringe to needle for loss of resistance technique.Aspirate to ensure proper placement of the needle bevel in epidural space.Warning: when blood or spinal fluid is returned in the plunger barrel, the needle has been placed incorrectly.Stop.Remove the needle and attempt new puncture." a corrective action is not required at this time as a potential root cause could not be determined based upon the information provided and without a sample.The reported complaint of the epidural needle tip having less curvature than a previous needle could not be confirmed based on the sample received.The actual complaint sample was not returned; only a representative sample was received.The customer also returned another needle from a different supplier (pajunk) that was previous used for this kit #.The two returned needles were compared with each other and both looked the same.A device history record review was performed on the epidural needle with no evidence to suggest a manufacturing related cause.Therefore, the potential cause of the needle tip not having the same curvature could not be determined based upon the information provided and the actual complaint sample.
|
|
Event Description
|
It was reported that the new needle tuohy, the tip has less curvature than before and as a consequence 18 patients suffered wet needling, the epidural administration broke the ligament of dura mater, during the two last months.Patient complications: strong headaches, which can become chronic.It was reported that the patients are currently doing fine.
|
|
Search Alerts/Recalls
|
|