• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDELA LLC BREASTPUMP PNSA STARTER; PUMP, BREAST, POWERED

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDELA LLC BREASTPUMP PNSA STARTER; PUMP, BREAST, POWERED Back to Search Results
Model Number 57081
Device Problems Crack (1135); Extrusion (2934)
Patient Problem No Information (3190)
Event Date 01/02/2018
Event Type  malfunction  
Manufacturer Narrative
The customer was sent a response email, requesting that she contact customer service for assistance.As of the date of this report, one attempt to contact to the customer to get additional information and to arrange for replacement of the power supply was unsuccessful.The issue with a damaged rev p power supply for the pump in style device is currently being evaluated under an investigation for (b)(4).A conclusion regarding this issue cannot be made at this time.
 
Event Description
On (b)(6) 2017, the customer alleged to medela llc via email that when she removed the power supply for her pump in style breast pump from the wall, the housing cracked and the electronics are hanging out.
 
Manufacturer Narrative
A replacement power supply was sent to the customer.When the product was received and evaluated, it was identified as a rev m and not a rev p, as previously reported.This issue with a damaged rev m power supply for the pump in style device was addressed in investigation ir12-0037.The investigation found that they were being damaged during shipment from the manufacturer to medela.This damage was causing the plastic housing to fail prematurely when subjected to normal use and foreseeable misuse.The packaging used by the manufacturer to ship the power supply to medela was not robust enough to handle all of the potential shipping, handling, and abuse conditions that could arise from logistics of the consolidation process.As a result of the investigation, the shipping and consolidation process was modified to reduce the handling and potential for double stacking of the skids.The shipping packaging strength was also increased to further protect the power supply during shipping.Since then, as a part of routine continuous improvement activities, a rev p power supply has been distributed to market, manufactured under a revised design and by a different manufacturer.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BREASTPUMP PNSA STARTER
Type of Device
PUMP, BREAST, POWERED
Manufacturer (Section D)
MEDELA LLC
1101 corporate dr
mchenry IL 60050
MDR Report Key7167675
MDR Text Key97668132
Report Number1419937-2018-00005
Device Sequence Number1
Product Code HGX
Combination Product (y/n)N
PMA/PMN Number
K031614
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Type of Report Initial,Followup
Report Date 04/25/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/05/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Model Number57081
Device Catalogue Number57081
Device Lot NumberREV M/LOT 5112
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/13/2018
Distributor Facility Aware Date01/02/2018
Date Manufacturer Received02/15/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-